Problem
It is too warm in the
appliance.
The green control
light (figure "/2) is
not lit.
Increased formation
of frost on the upper
edge of the
appliance.

After-sales service

You can find an after-sales service point
near to you in the telephone directory or
in the list of after-sales service points.
When you call the after-sales service,
quote your product number (E no.) and
the production number (FD no.) of your
appliance.
You will find this information on the
rating plate. Figure (
14
Possible cause
The chest lid is being
opened frequently.
Lots of food has been
placed in the freezer.
The ventilation
openings are
covered. Figure '
The appliance is
beside a heat source.
The appliance is
switched off.
Power failure; the
fuse protection has
been switched off;
the mains plug is not
firmly inserted.
The drain plugs are
not in the correct
position.
The transport locks
were not removed
The chest lid is being
opened frequently.
Remedy
Do not open the chest lid
unnecessarily.
Turn the temperature selector to
position 8 a long time before
placing the frozen food inside.
Figure "/1
Remove any obstructions.
Maintain the minimum distance or
use an insulating plate.
Connect the mains plug.
Check whether there is power,
check the fuses.
Insert the drain plugs correctly on
the floor of the appliance and on the
rear of the appliance (see chapter
"Defrosting").
Remove the transport locks,
figure # (see section "Installing the
appliance").
Do not open the chest lid
unnecessarily.
Please help us to avoid unnecessary
journeys by quoting the appliance and
production number. This will save you
the additional associated costs.