DA440HU: 99900782: 19990120 Model DA440HU Hydraulic Driven Underdeck Compressor IOWA MOLD TOOLING CO., INC. BOX 189, 500 HWY 18 WEST, GARNER, IA 50438 TEL: 515-923-3711 TECHNICAL SUPPORT FAX: 515-923-2424 MANUAL PART NUMBER 99900782...
Page 2
DA440HU: 99900782: 19980224 PRECAUTIONS Read before operating your compressor! DANGER EXPLODING TANK WILL CAUSE DEATH, SERIOUS INJURY OR PROPERTY DAMAGE Drain air tank after each use to prevent moisture build-up and corrosion which leads to tank failure. Assure that tank and compressor relief valves work properly, and are at correct pressure settings.
DA440HU: 99900782: 19980224 TABLE OF CONTENTS PARA TITLE PAGE Section 1. GENERAL INFORMATION 1-1. INTRODUCTION ....................1-1 1-2. ORDERING INFORMATION .................. 1-2 Section 2. INSTALLATION 2-1. GENERAL ......................2-1 2-2. PTO AND PUMP INSTALLATION ................2-1 2-2-1. PTO INSTALLATION ....................2-1 2-2-2.
Page 4
DA440HU: 99900782: 19980224 RECOMMENDED SPARE PARTS LIST 1 Year Supply DA440HU HYDRAULIC DRIVEN TOPDECK COMPRESSOR For Manual: 99900782 This spare parts list does not necessarily indicate that the items can be expected to fail in the course of a year. It is intended to provide the user with a stock of parts sufficient to keep the unit operating with minimal down-time waiting for parts.
DA440HU: 99900782: 19941223 SECTION 1. GENERAL INFORMATION 1-1. INTRODUCTION 1-2. ORDERING INFORMATION NOTE A NOTE IS USED TO EITHER CONVEY ADDITIONAL INFORMATION OR TO PROVIDE FURTHER EMPHASIS FOR A PREVIOUS POINT. CAUTION A CAUTION IS USED WHEN THERE IS THE STRONG POSSIBILITY OF DAMAGE TO THE EQUIPMENT OR PREMATURE EQUIPMENT FAILURE.
DA440HU: 99900782: 19941223 SECTION 2. INSTALLATION 2-1. GENERAL CAUTION IT IS IMPORTANT THAT ROOM BE ALLOWED FOR FULL 2-2. PTO AND PUMP INSTALLATION ENGAGEMENT OF THE PTO. MODIFY THE EXHAUST OR OTHER OBSTRUCTIONS AS NEEDED. CAUTION AVOID SHARP BENDS IN THE SHIFTER CABLE. ALL BENDS SHOULD HAVE AT LEAST A 6"...
DA440HU: 99900782: 19990120 WARNING 2-2-2. DRIVELINE AND PUMP THE INSTALLER OF THE DRIVELINE MUST INSPECT INSTALLATION THE FINAL POSITION OF THE DRIVELINE TO DETERMINE WHETHER ITS LOCATION PROVIDES SUFFICIENT PROTECTION TO AN OPERATOR, OR OTHER PERSONNEL, FROM HAZARDS ASSOCIATED WITH A ROTATING DRIVELINE. IF PROTECTION IS INSUFFICIENT, THE INSTALLATION OF A GUARD IS REQUIRED.
DA440HU: 99900782: 19941223 2-4. OIL COOLER (OPTIONAL) Oil coolers vary in their installation dependent on available space and other considerations. Install the oil cooler either in front of the carrier vehicle’s radiator or, as an alternative, in a protective structure which is cooled by an electric fan.
DA440HU: 99900782: 19950719 SECTION 3. OPERATION 3-1. INTRODUCTION CAUTION 1000 RPM MAX. Operating this unit in excess of 1000 RPM, measured at the compressor flywheel, will void your warranty. Engine RPM may be different. 3-3. SYSTEM SHUTDOWN. 3-2. OPERATION CAUTION THE HYDRAULIC OIL TEMPERATURE MUST NOT BE ALLOWED TO EXCEED 190°F (88°C).
DA440HU: 99900782: 19941223 NOTE BE THOROUGHLY FAMILIAR WITH THE FOLLOWING STEPS AND PREPARED TO PERFORM THEM IN AN UNINTERRUPTED SEQUENCE. IF THIS IS NOT DONE, EXCESSIVE OIL WASTE WILL OCCUR. CAUTION DO NOT ALLOW THE RESERVOIR LEVEL TO DROP BELOW 1/3 CAPACITY DURING THIS OPERATION. 4-3-5.