SENTRON SUPERSWITCH
Switch Disconnector Fuse - Size 4
3KL84...-.. (500A-800A)
3KA84...-..(630A-1600A)
Required tools
2.5 mm
Contents
Assembly
Mounting Details:
1 mm
3
13 mm
0.5 x 3 mm
19 mm
EN
Hazardous voltage will cause death or serious injury. Turn off and
lock out all power supplying this device before working on this device.
Replace all covers before power supplying this device is turned on.
Installation & Maintenace must be carried out by qualified personnel.
PZ 5
1x
2P: 2x
3P: 3x
4P: 4x
2x
3K.84..-5
M10 x 30
For 3KL8
2P/3P/4P : M8 x 20 (4x)
Torque 10....14 Nm
(Not in scope of supply)
Permissible mounting position
IEC 60947-1
IEC 60947-3
DANGER
!
NOTICE
1x
8UC64..
2P: 4x
3P: 6x
4P: 8x
3K.84..M12 x 40
A
20.5
M8 (4x)
Center of
Shaft
Drilling Plan for mounting plate
POLE
A
L1V30606645004-01 | 01

Advertisement

loading

Summary of Contents for Siemens 3KL84 Series

  • Page 1 SENTRON SUPERSWITCH Switch Disconnector Fuse - Size 4 3KL84...-.. (500A-800A) IEC 60947-1 3KA84...-..(630A-1600A) IEC 60947-3 DANGER Hazardous voltage will cause death or serious injury. Turn off and lock out all power supplying this device before working on this device. Replace all covers before power supplying this device is turned on. NOTICE Installation &...
  • Page 2 Connection 3KL831.../3KA831..1 mm 3KL8322.../3KA822..1 mm Max. Lug Size..2 X 185 mm M12 X 40 Max. Busbar Size..2 X 50 X 5 mm M12 x 40 Torque 20 Nm to 28 Nm 3KL823../3KA823..5 Neutral Link Max. Lug Size..120 mm M10 x 30 (2x) Torque 10 Nm to 28 Nm Provision for Fuse monitoring Assembly...
  • Page 3 Assembly Mounting Details for Front Drive 8UC6414-1BB00 2.5 mm 297.7...325.7 Panel Door 1.5..4Thk Coupler Pz5 X 13.5 PZ 5 2.1...2.4Nm 45.5 1 8UC Coupler depth adjustment Use Depth Setting Templet - 8UC6046-2 Adjust Depth of Drive as per dimensional plan Assembly Phase Barrier: 3KX84330AE...
  • Page 4: Terminal Cover

    Assembly Terminal cover 2P : 3KX84310AF 3P : 3KX84310AE 4P : 3KX84310AG 0.5 x 3 mm Rear Cover 2P : 3KX84360AF 3P : 3KX84360AE 4P : 3KX84360AG Rear Phase Barrier Kit 2P/3P/4P : 3KX84469AE 0.5 x 3 mm L1V30606645004-01 | 04...
  • Page 5 Assembly Fuse Cover: 2P (DIN/BS): 3KX84300HF/3KX84300JF 3P (DIN/BS): 3KX84300HE/3KX84300JE 4P (DIN/BS): 3KX84300HG/3KX84300JG Fuse Cover Phase Barrier kit 3KX84409AE Unlocked Locked 0.5 x 3 mm 0.5 x 3 mm 2P/3P/4P - Replace phase barrier in position 1 with Fuse Cover Phase Barrier 2P : Add Fuse cover phase Barrier in Position 3 2P : Add Fuse cover phase Barrier in Position 4 3P : Add Fuse cover phase Barrier in Position 5...
  • Page 6 Information Dimension Details for SDF in Enclosure Mounting Dimensions Outline of Enclosure Information Overall Dimensional details 3P(3KL8)/3P+N 264.4 154.4 17.5 299.7..324.7 4 THICK 32.5 INTERLOCKING REAR COVER LEVER 70.2 AUXLIARY FUSE PHASE SWITCH COVER 51.7 REAR PHASE BARRIER BARRIER OFF POSITION NEUTRAL INDICATOR TERMINAL...
  • Page 7 Information 3KA8: 3P+N 299.7 ..324.7 17.5 Incoming 32.5 70.2 OFF POSITION INDICATOR AUXLIARY SWITCH Outgoing 60.2 3KA8: 2P 3KA8: 4P For missing Dimension refer 3P+N For missing Dimension refer 3P+N Type 3KA..2..3KA..3..64.4 153.9 842/843/844 3KA..2..3KA..3..58.4 159.9 845/846 L1V30606645004-01 | 07...

This manual is also suitable for:

3ka84 seriesSentron superswitch 3kl84 seriesSentron superswitch 3ka84 series