  • Page 1 CLIMIA Local room air conditioner CMK 2600 Operating manual Edition 3.0 English...
  • Page 2 CLIMIA...
  • Page 3: Table Of Contents

    Local room air conditioner CMK 2600 Table of Contents 1.0 Safety information 2.0 Environmental protection and recycling 3.0 Guarantee 4.0 Intended use 5.0 Transportation and packaging 6.0 Unit description 7.0 Operation 8.0 Before commissioning 9-10 9.0 Commissioning 10.0 Shutdown 10-11 11.0 Filter cleaning...
  • Page 4: Safety Information

    Appropriate hazard prevention instructions are observed. • Modification of the units and measures must be taken to components supplied by CLIMIA prevent risks to people when • The unit may only be stored and is not permitted and can cause...
  • Page 5: Environmental Protection And Recycling

    Local room air conditioner CMK 2600 • Repairs of any kind may only be • The tool used must be approved The manufacturer/supplier assumes carried out by certified specialist for working with flammable no liability for damages arising from personnel. Intervention in the refrigerants.
  • Page 6: Transportation And Packaging

    CLIMIA 5.0 Transportation and packaging Control panel The units are shipped in sturdy IR receiver transport packaging. Check the unit immediately after delivery and make a note of any damage (please take photos of the damage) or missing parts on the delivery note.
  • Page 7: Operation

    Local room air conditioner CMK 2600 7.0 Operation The system can be operated by means of the control panel on the unit or via the standard infrared remote controller. The functional operation of the keys is identical, however, the designation may vary. The batteries must be correctly inserted before the infrared remote control is used.
  • Page 8 CLIMIA Cooling mode "Cool" Ventilate mode "Fan" "Timer" 1. Attach the exhaust air hose to a 1. Switch the unit on with the "On/ With the timer function of the IR wall pass-through or window. Off" key . remote control, the unit can be switched on or off with a time 2.
  • Page 9: Before Commissioning

    Local room air conditioner CMK 2600 8.0 Before commissioning Conduct the warm exhaust air away The unit is positioned at the desired • Check location with the discharge side whether the pointing into the room. When stopper in the CAUTION!
  • Page 10: Commissioning

    CLIMIA 9.0 Commissioning 10.0 Shutdown Via a wall pass-through Temporary shutdown Before every commissioning the air inlet and outlet openings should The hose supplied is firmly attached be checked for foreign bodies and If it is planned to shut down the unit to a wall pass-through.
  • Page 11: Filter Cleaning

    Local room air conditioner CMK 2600 11.0 Filter cleaning 12.0 Care and maintenance Permanent shutdown Ensure that units and components The unit is equipped with an air Regular care and observation are disposed of in accordance with filter. This can be withdrawn from of some basic points will ensure local regulations, e.g.
  • Page 12: Installation Scheme For Wall Pass-Through

    CLIMIA 13.0 Installation scheme for wall pass-though (accessory) External grill Non-return flap Sealing cover Telescopic tube Fig. 11 Installation example Installation instructions 1. Create a core hole in the exterior 4. Fasten the protection grid on the wall (max. wall thickness outside of the wall with 4 screws.
  • Page 13: Troubleshooting And Customer Service

    Local room air conditioner CMK 2600 14.0 Troubleshooting and customer service The unit and components are manufactured using state-of-the-art production methods and tested several times to verify that they function correctly. If malfunctions should occur, please check the unit as detailed in the list below.
  • Page 14: Electrical Wiring Diagram

    CLIMIA 15.0 Electrical wiring diagram Fig. 12 Connection diagram CMK 2600...
  • Page 15: Unit Illustration

    Local room air conditioner CMK 2600 16.0 Unit illustration Fig. 13 Exploded view of unit CMK 2600...
  • Page 16: Spare Parts List

    CLIMIA 17.0 Spare parts list Designation Unit base Conveyor rollers Condensate pump Impeller for condensate pump Liquid level switch Compressor Condenser Evaporator Front wall Fins Fan impeller (condenser fan) Fan motor Fan impeller (evaporator fan) Filter grille Back wall Display board...
  • Page 17: Technical Data

    Local room air conditioner CMK 2600 19.0 Technical data Series CMK 2600 Operating mode Local room air conditioner for cooling Nominal cooling output Energy efficiency ratio - cooling Energy efficiency ratio cooling EER Power consumption, annual, (500h) Application area (room volume), approx.
  • Page 18: Ec Declaration Of Conformity

    We hereby declare that the units named below, as produced and sold by us, satisfy the relevant basic requirements of the EU directives, EU safety standards and product-specific EU standards. Intakt GmbH Name of Manufacturer: Climia - Klima- und Wärmetechnik Niemeierstraße 13 D - 32758 Detmold Name of the CE representative: Intakt GmbH Climia - Klima- und Wärmetechnik...
  • Page 20 Intakt GmbH Climia - Klima- und Wärmetechnik Niemeierstraße 13 D - 32758 Detmold...