Page 2
Déclaration de conformité | Declaración de conformidad | Dichiarazione di conformità TPP Techno Plastic Products AG – 8219 Trasadingen, Switzerland declares on its own responsibility that the product | erklärt in alleiniger Verantwortung, dass das Produkt | déclare sous sa responsabilité exclusive, que le produit | declara bajo su propia responsabilidad que el producto | dichiara sotto la propria responsabilità...
TPP Techno Plastic Products AG CH-8219 Trasadingen, Switzerland T +41 52 687 01 87 F +41 52 687 01 77 info@tpp.ch www.tpp.ch Customer service Please contact your local TPP Techno Plastic Products AG representative, see www.tpp.ch or contact info@tpp.ch. www.tpp.ch...
Safety notes 1) Do not use or charge TPP Pipettor Turbo-Fix in an atmosphere with danger of explosion. Also, do not pipette highly flammable liquids such as acetone or ether. 2) When handling dangerous substances, comply with the material safety data sheet (MSDS) and with all safety guidelines such as the use of protective clothing and safety goggles.
Installation Charging the battery A full charge takes 3.5 hours. Before the first use, TPP Pipettor Turbo-Fix should be charged until the battery charge indicator (4) turns green, showing that the battery is full. When the battery charge indicator (4) starts flashing red, TPP Pipettor Turbo-Fix can be used for around 100 pipetting cycles before shutting down.
“to deliver” (TD) pipettes that are not of the “blow-out” type (blow-out pipettes have two thin rings or a frosted band around the neck). TPP Pipettor Turbo-Fix is featured with a “TURBO” mode. Plug the mains adapter cable into the pipette controller and turn the thumb wheel completely to the right for maximal speed.
Page 8
Troubleshooting Problem Probable cause Remedy Pipette drips Pipette is damaged or not fully Reinsert a new pipette and push it all the way into the (leak in the system). inserted in the nose piece (7). nose piece. Make sure that the pipette mount orientation is correct (see section 4.1).
Maintenance Cleaning and servicing TPP Pipettor Turbo-Fix can be cleaned with a cloth moistened with soapy water or with a 70 % ethanol. Never use acetone or other solvents. The nose piece housing (7b, 7f), the pipette mount (7e) and the filter rubber (7c) can be autoclaved at 121 °C.
TPP Pipettor Turbo-Fix - Operating instructions V07 Technical Data Technical Data Pipetting speed max. 13.5 ml/s (with a 50 ml serological pipette) Battery Type: rechargeable, Lithium Polymer, 7-10 V, min. 550 mAh Typical charging time: 3.5 hours Charging cycles: 500–1000 (when charging as indicated) Running time: at least 5500 cycles of aspiration and dispensing of 25 ml.
Need help?
Do you have a question about the Pipettor Turbo-Fix and is the answer not in the manual?
Questions and answers