  • Page 2 1 Single Zone System. SmartCom Mulitizone 1/L 2/N S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 LIVE NEUT Black Bulb Sensor Outside 40VA Sensor Trans (where applicable) S-0700 Relay eg E.M.S. L1 (HOT) 120V 60Hz 1 Ph 20 amp Supply S-0755 Relay...
  • Page 3 2 Split Zone System.
  • Page 4: Multizone System

    3 Multizone System.
  • Page 5 4 Single Zone System c/w Motorised Damper. SmartCom Mulitizone 1/L 2/N S/R0S/R1 D0 D1 O0 O1 B1 B0 B2 C2 C0 C1 66 64 20 LIVE NEUT Black Bulb Sensor Outside 40VA Sensor Trans (where applicable) S-0700 Relay eg E.M.S. L1 (HOT) 120V 60Hz 1 Ph 20 amp Supply...
  • Page 6 5 Modulating Split Zone System.
  • Page 7 6 Independently Modulating Split Zone System...
  • Page 8 7 Multizone Modulating System...
  • Page 9: Schematic Diagram

    8 Modulation Damper and Pressure Switches The fan damper is wired via a plug and socket arrangement. The socket is connected to the assembly via a bracket. Release the loose plug and FIXED CONNECTION remove the cap via two screws. SOCKET Connect incoming...
  • Page 10 9 Schematic Two Zone One Fan ARC System.
  • Page 11 (17mm) End Vent L104102 L104101 L104100 L104103 Orifice Plate (16mm) (24mm) (27mm) (28mm) End Vent Suction (All Models) Minimum Fire 0.5” to 1” WG Maximum Fire 2.5” to 3” WG Please contact an AmbiRad representative for installations over 4000’ elevation...
  • Page 12 12 SmartCom³ ARC Commissioning. For ease and swiftness of initial start-up, the immediately with standard Infrared Radiant SmartCom³ range of electronic controllers is heaters. supplied factory pre-set to default settings as described in the SmartCom³ Installation and To alter the control system to a single or multi-zone ARC systems and operated along User Manual ref US/SCOM/29.
  • Page 13 Notes: Remote Door Interlock MASTER & SLAVE (NETWORK) EXTERNAL / DOOR FROST ONLY When setting up a SmartCom³ Master and Slave (Network) system, the master controller will display error message during SmartCom³ controllers can be connect to a commissioning. This will clear once the door interlock, remote frost stat or permanent commissioning is complete.
  • Page 14 Fishers, Indiana 46038 Telephone 317-577-0337 Facsimile 317-842-3989 Website www.ambirad.com/us For the Distributor Nearest please AmbiRad is a registered trademark of AmbiRad Limited. Because of continuous product 1-888-330-4878 call innovation, AmbiRad reserves the right to change product specification without due notice.