6). Press the enter button to wait for the menu to appear. A sequence of messages displaying the eoBd protocols will be observed
on the display until the vehicle protocol is detected.
If the scan tool fails to communicate with the vehicle's Pcm (Power control module) more than three times, a "LInKInG error!"
message shows up on the display.
Verify that the ignition is on.
check if the scan tool's eoBd connector is securely connected to the vehicle's dLc.
Verify that the vehicle is eoBd compliant.
turn the ignition off and wait for about 10 seconds. turn the ignition back to on and repeat the procedure from step 5.
If the "LInKInG error" is displayed, then there might be problems for the scan tool to communicate with the vehicle.
contact Sealey technical Support or local distributor.
7). View a summary of system status (mIL status, dtc counts, monitor status) on screen. Wait a few seconds or press any key for
diagnostic menu to come up.
If more than one module is detected, you will be prompted to select a module before testing.
Use the SCROLL button to select a module and press the ENTER button to confirm.
5.1.

Read Codes

reading codes can be done with the key on engine off or with the key on engine running.
Stored codes are also known as "permanent codes". these codes cause the control module to illuminate the malfunction indicator light
(mIL) when emission-related fault occurs.
Pending codes are also referred to as "continuous monitor codes". they indicate problems that the control module has detected during
the current or last driving cycle but are not considered serious yet. Pending codes will not turn on the malfunction indicator lamp (mIL). If
the fault does not occur within a certain number of warm-up cycles, the code clears from memory.
1). Select (read codes) and press (enter) in diagnostic menu. If there are some codes, the screen will display the codes as shown
below:
note: there is a navigation bar in red to show the position for chosen item, also shows X/X at the top right corner to remind the user.
2) use the ScroLL button to select Stored codes or Pending codes from the read codes menu and press the enter button.
© Jack Sealey Limited
monitor Status
mIL status
off
codes found
6
monitors n/A
3
monitors oK
3
monitors Inc
5
control module
engine
module $A4
diagnostic menu
read codes
erase codes
View freeze frame
I/m readiness
Vehicle Information
Original Language Version
1/2
1/7
VS8812 | Issue 1 27/02/17