20
9.

Technical Data

Rated operating voltage
Operating voltage range
No-load current at UB=12 V DC
4 Analogue inputs:
- Operation as Detector group (In1 with clear function):
- Voltage
- End of line resistor
- Monitoring range
- Monitoring form "Double balanced":
- Resistor values for evaluation
Environmental class as per VdS / EN 50131-3
Operating temperature range
Storage temperature range
Relative humidity
Weight
Dimensions
Conformity:
Module 013930 as per EN 50131-3, Security grade 3, Environmental Class II
As per SES-EMA-RL-T2:2010-08
Honeywell Security and Fire
Novar GmbH
Johannes-Mauthe-Straße 14
D-72458 Albstadt
www.honeywell.com/security/de
Mounting and Connection Instructions IB2 Bus Expander
12 V DC
10.5 V DC to 15 V DC
max. 65 mA
8 V DC, stabilized, short-circuit protected
fixed value 12k1 or 10k, freely programmable 4k
to 14k6 (depending on monitoring range)
±20%, ±30%, or ±40% (programmable)
£
R800, 1k, 2k, 4k, 5k,
II / Class II
-10 °C to +45 °C
-25 °C to +70 °C
93% non-condensing
163 g
112 x 158 x 20 mm
P00184-10-002-05
2017-05-10
© 2017 Novar GmbH
³
17k5 (fixed values)