Conversion To Another Type Of Gas; Jet Table; Changing The Jets; Changing The Main Jets - Miele SmartLine CS 7101 Operating And Installation Instructions

Gas wok burner
Table of Contents

Advertisement

Conversion to another type of gas

Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an authorised and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed. Disconnect the cooktop
from the electricity supply and turn
off the gas supply.

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Gas type
Main jet
Natural gas
2 x 1.20 / 0.90
ULPG
2 x 0.67 / 0.46

Changing the jets

 Disconnect the cooktop from the
electricity supply and turn off the gas
supply.
When converting to another type of
gas, both the main and small jets
need to be changed.
66

Changing the main jets

 Remove the burner caps  and
Small jet
0.88 / 0.42
 Using an M7 socket spanner,
0.52 / 0.23
 Fit the correct jets securely (see jet
 Secure the jets against inadvertent
burner head .
unscrew the main jets .
table).
loosening with sealing wax.

Advertisement

Table of Contents
loading

Table of Contents