CONTENTS Warning Caution Particular Warning! Please note: Important Figure 1 Haze Functions Description Getting ready Mounting Set Up Operation Troubleshooting Maintenance Product Specification If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Thank you for selecting our Haze machine, you already own the high-tech, and user-friendly Haze! Better read the manual thoroughly before operation, follow instruction will help you have a smooth handling with Haze machine to achieve the most satisfactory fog effect, it will also assist unit to further prolong life time as a whole.
Page 4
• Keep case closed while operating. Put the machine in drafty place. Do not insert objects into air vents. Allow 100CM space or above around the machine for proper ventilation. • Keep Haze machine away from flames and flammable items. Never aim the nozzle at open flames or sparks. Use only high quality water-based Haze fluid. Never put flammable substances into the tank. • Machine must cool down before cleaning, servicing or storing. • Never put any flammable material (lipid, gas, perfume etc.) into the tank, read the user manual thoroughly before operation. • Better use our high quality water-based fog fluid, random use with other Haze fluid may jam the pipe, or even erode the components inside. • Keep sufficient fluid in tank. Operating the unit without sufficient fluid, the pump will stop working. • If any abnormal running occurs, stop it immediately, empty the fluid, and bring the done up unit (recommend original box) to your agent or dealer for servicing. Make sure all fluid is empty from the tank before moving or shipping. • Never drink fog fluid. If ingested, call a doctor immediately. If fluid contacts eyes or skin, rinse skin thoroughly with water. • Read user manual instructions thoroughly before operating. Follow the instruction. Never remove warning or informative labels from the unit. Important Safeguards • Read all instruction • Products for indoor use only. Keep away from liquids. Never operate in rain or in damp conditions. • Unit must be grounded.
Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact your local dealer. Particular Warning : Please install the product correctly according to the instruction of the user manual. To avoid any accident, it is not allowed to install the product with any way not instructed on the user manual. If accident happens because users do not install the product according to the instruction of the user manual, the manufacturer will not take any responsibility.
Page 6
Figure1 Haze Functions A. Hanging Bracket with handle screw (used as a tripod) B. Tank J. Manual Fog C. Fixed Ring K. Power ON/OFF D. Air Deflector L. Fuse E. Sponge M. Electric Power Input F. Smoke Output N. Safety Hole G. Control Socket Connection O. Pad H. Two pin Dip Switch for Fluid Sensor LED Indicator for No Fluid Detection...
7. Excellent design of 1.5 liter liquid tank has no worry of oil leaking when being operated up spray or forward spray. 8. Very durable and able to keep working long time. 9. Self-cleaning system: 100 seconds after shot down, the machine stops working. During the 100 seconds, the machine does self- cleaning of oil residue in the pipe. 10. Function of detecting no fluid. The machine stops working automatically when fluid is run out, and LED light indicates no fluid status. This function can be selected OFF. 11. Can do fogging manually or by VT-1 controller. Simple and humanized design let use of miniMYSTYQUE 200 be easier. 12. Light and thin housing can be easily hung up, located on the ground, or installed in any places where need the equipment.
If damage has occurred during shipping, or if components are missing, please contact your local dealer immediately. Your package should include: 1.One Haze Machine 2.One product user manual Mounting miniMYSTYQUE 200 is shipped complete, ready to use. The bracket is installed before shipping, the unit can be hung in any position. Fasten the effect fan onto firm trussing (Use a 15-kg rated or stronger C-clamp bolted onto the bracket, enhancing safety necessarily with safety cables). Allow enough space (around 20cm) on all sides for proper cooling.
Set Up 1. Open the shipping carton and carefully remove the unit from the shipping carton; 2. Be sure to remove packing material from around the Haze machine, especially near the nozzle; 3. Set the Haze machine on a dry, flat surface; 4. Use only high quality, water-based fog fluid; 5. Firmly attach the remote control mechanism to socket (Figure1-G) on the back of the unit; 6. Plug mains power cord from the Haze machine into appropriate power supply socket. Wait about 70 seconds for heating element to heat up; 7. Refer to your controller manual for operation details; 8. Moving the machine during operation could probably get air entered into the liquid pipe and affect smoothness of fog blasts. If this happened, press the “Manual Fog”...
2. When the machine is started for 80 seconds, the machine will detect i f there is fluid currently. 3. When the machine has no fluid, the machine takes about 30 seconds to detect. After 30 seconds and there is no fluid, the machine stops working automatically. 4. After filling the fluid, the “manual fog” button must be turned OFF, and then turned ON to reset. Operation Remote Control Operation ............... For best result, use VT-1 wired controller. 1. Firmly attach the remote control mechanism to socket (Figure1-G) on the back of the unit; 2. Plug mains power cord from the machine into appropriate power supply socket, the red LED upon the controller is lighted; 3. The volume adjustment knob on the controller is with the switch; 4. Turn the knob counterclockwise to the end to switch off, the fog is off, the green LED upon the controller is lighted; 5.
Page 11
VT-1 wired controller A-1/4” stereo jack B- Knob C- Green LED (Volume output) D- Red LED (power) Controller power cord length: 3 m; Connector: 1/4 “stereo jack; Function: Air volume adjustment & ON/OFF; Model VT-1 Cable Length Effective Distance Connector 1/4” stereo jack ON/OFF Function Volume adjustment Dimension (LxWxH) 90 x 50 x 39 mm Weight 0.257 kg...
Manual Fogging Operation .............. 1. As long as heating is completed, turn on the “ Manual fog” button, the machine with maximum output fogging; 2. Turn off the “Manual fog” button to stop. 3. When the machine stops fogging, please do not unplug the machine immediately, but wait 100 seconds to let the machine automatically clean the fluid left in the pipe. This is to avoid causing negative effect when used next time. Troubleshooting This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps. If the problem persists, refer servicing to a qualified technician.
Page 13
Power Connected, Fog Blasts not Smooth: Moving the machine during operation could probably get air entered into the liquid pipe and affect smoothness of fog blasts. If this happened, press Manual Fog button to fog for a moment. Until the air is dispersed from the pipe, the machine will recover its normal fogging. Should there be any low fog emitted, running noisily or hindered fogging, please wait for self-cleaning and pull out the plug immediately. Check if string enough fluid, if the pipe connected to the tank is clean, if there’s air inside the pipe, if the liquid flows, if not, plug-in again; still persists abnormal running, and If causation is unclear, stop running to avoid any damage, shut down to cool it, and bring unit to your local agent or appointed service place for inspection, prohibit any dismantlement by yourself.
Maintenance Before doing maintenance, please make sure that the power is cut, the power cord is unplugged, and the machine itself has cooled down. The maintenance must be done by qualified person. 1. The fluid is not allowed to get dirty. Be sure to always clean or replace the caps on the tank (Replace the caps on the tank directly. This kit includes cap, pipe and filter) and tight the cover of the Haze machine tank immediately after filling. 2. Prolonged use, the nozzle may be clogging by impurities, periodically use tools to clean the nozzles, keep the nozzle unobstructed. 3. Prolonged use, please clean the air inlet regularly. 4. Prolonged use, sponge inside the vent may accumulate oil, periodically cleaned out or replaced with a new sponge. 5.
Need help?
Do you have a question about the miniMYSTYQUE 200 and is the answer not in the manual?
Questions and answers