  • Page 1 ENGLISH MYSTYQUE 400 DMX Version 1.1...
  • Page 2: Table Of Contents

    CONTENTS Warning Important safeguards Caution Please note: Important Figure 1 DMX HAZE Functions Description Getting ready Mounting Set Up DMX Connector Pin Assignment Functions of the buttons Very Important Operation Figure 2 DMX Chart Troubleshooting Maintenance Product Specification If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • Page 3: Warning

    Thank you for selecting our DMX haze machine, you already own the high-tech, professional DMX haze! Better read the manual thoroughly before operation, follow instruction will help you have a smooth handling with DMX haze machine to achieve the most satisfactory haze effect, it will also assist unit to further prolong life time as a whole.
  • Page 4 • Without changeable structure by non-qualified user, please do not open the cover or have any change at will, otherwise, it may cause accident! • Haze machine is for adult use. Keep out of reach of children. Never leave the unit running unattended. • Haze machine nozzle gets hot over 200 degrees (centigrade) during use. Don’t touch! Maintain a safe distance over 100CM.
  • Page 5: Important Safeguards

    • If any abnormal running occurs, stop it immediately, empty the fluid, and bring the done up unit (recommend original box) to your agent or dealer for servicing. Make sure all fluid is empty from the tank before moving or shipping. • Never drink fog fluid. If ingested, call a doctor immediately. If fluid contacts eyes or skin, rinse skin thoroughly with water.
  • Page 6: Caution

    Caution! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact your local dealer. Particular Warning : Please install the product correctly according to the instruction of the user manual.
  • Page 7: Figure 1 Dmx Haze Functions

    Figure1 DMX HAZE Functions A. Hanging Bracket with handle screw (used as a tripod) B. Tank K. DMX 3 pin XLR Output C. Quick Connector L. DMX 3 pin XLR Input D. Fixed Ring M. Manual Fog E. Air Deflector N. Power ON/OFF F. Sponge O. Fuse G. Smoke Output P.
  • Page 8: Description

    • Equipped with 0-90 degree adjustable air deflector. • Heavy-duty. Able to keep working long time. • Self-cleaning function: The machine design of machine stops working after a delay of 100 seconds, automatically clear the tubing of the remaining liquid. • Easy understanding LED screen and intelligent design of software control. • Could be used with the VT-1 controller (optional). Simple and user- friendly design makes MYSTYQUE 400 DMX easier to use. • The streamline housing could be hanging, side hanging, landing installation, easy to set in various occasions.
  • Page 9: Getting Ready

    Your package should include: 1.One DMX Hazer 2.One product user manual Mounting MYSTYQUE 400 DMX is shipped complete, ready to use. The bracket is installed before shipping, the unit can be hung in any position. Fasten the effect fan onto firm trussing (Use a 15-kg rated or stronger C-clamp bolted onto the bracket, enhancing safety necessarily with safety cables). Allow enough space (around 20cm) on all sides for proper cooling.
  • Page 10: Set Up

    Set Up 1. Open the shipping carton and carefully remove the unit from the shipping carton; 2. Be sure to remove packing material from around the haze machine, especially near the nozzle; 3. Set the haze machine on a dry, flat surface; 4. Connect the quick connector with the liquid tank cap (Figure 1-C). Be sure of well connection. Use definitely water based liquid of good quality; 5. Plug mains power cord from the haze machine into appropriate power supply socket. Wait about 40 seconds for heating element to heat up;...
  • Page 11: Dmx Connector Pin Assignment

    DMX Connector Pin Assignment The machine provides a 3- or 5-pin XLR connector for DMX connection. The diagram below indicates pin assignment information. 5 pin XLR 3 pin XLR 1. Ground 2. Cold 1. Ground 5. N/A 2. Cold 4. N/A 3. Hot 3. Hot 2. Cold 1. Ground 5. N/A 1.
  • Page 12: Functions Of The Buttons

    Functions of the buttons 8.8.8.8. MENU: Function switching button; then have the numerical value changed by using UP and DOWN buttons. Setting of DMX address. Range of address value: DMX Address: address=001~512. A 5 1 2 Press UP or Down 1.5 seconds can change value continuously and fast, pressed UP/DOWN at the same time, value back to 1.
  • Page 13 Fluid inspection ON/OFF: ON/OFF setting of automatic inspection of fluid volume. 1. When this function is “0” means OFF, the machine F 0 00 cannot inspect volume of the fluid. This means that the machine will keep working even there’s no fluid. 2.
  • Page 14: Very Important

    Very Important Please do not pull out the power suddenly when the machine is in normal smoke condition. Control priority order: When both DMX console and VT-1 are connected to the machine, appears problem of priority among the panel control, DMX console and VT-1 controller. There’s no apparent priority among the three controls. The one which has change action gets the priority of control. 1.
  • Page 15 Continuous Fogging Operation ............Panel control, DMX signal is not connected. Press MENU to enter Volume adjustment, the picture U 1 00 shows the new machine default state; Press “Up” or “Down” to adjust smoke volume value U 0 20 (1 -100%), the picture shows the volume value is 20%; Press Manual Fog to starts continuous fogging status, 0 .
  • Page 16 Press again Timer to stop Timing fogging, red dot 00 2 disappears at the same time; When the machine stops fogging, please do not unplug p I CL the machine immediately, but wait 100 seconds to let the machine automatically clean the fluid left in the pipe.
  • Page 17 VT-1 wired controller A-1/4” stereo jack B- Knob C- Green LED (Volume output) D- Red LED (power) Controller power cord length: 3 m; Connector: 1/4 “stereo jack; Function: Air volume adjustment & ON/OFF; Model VT-1 Cable Length Effective Distance Connector 1/4” stereo jack ON/OFF Function Volume adjustment Dimension (LxWxH) 90 x 50 x 39 mm Weight 0.257 kg...
  • Page 18 DMX Control Operation ..............Setting DMX mode and DMX address by function buttons (figure 1-I) on both side of the LED screen, DMX operation has not started at this time; Press MENU enter to DMX mode, press Up or Down button C0 0 1 to set the DMX Mode, there are 3 DMX modes for choice: 1CH, 2CH, 4CH; Press MENU enter to DMX address, press Up or Down A5 1 2 button to set the DMX address;...
  • Page 19: Figure 2 Dmx Chart

    Figure 2 DMX Chart 1 CH DMX Value Volume 0-255 0%-100% 2 CH DMX Value Volume DMX Value ON/OFF 0-255 0%-100% 128-255 0-127 4 CH DMX Value Volume DMX Value ON/OFF DMX Value Duration DMX Value Interval 0-255 0%-100% 128-255 10-255 10-255s 2-255...
  • Page 20: Troubleshooting

    Troubleshooting This troubleshooting guide is meant to help solve simple problems. If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit operates properly, do not carry out following steps. If the problem persists, refer servicing to a qualified technician.
  • Page 21 is unclear, stop running to avoid any damage, shut down to cool it, and bring unit to your local agent or appointed service place for inspection, prohibit any dismantlement by yourself. • If fluid is run out, full the tank with fluid and press “Manual Fog” to reset. Very Important: Please do not pull out the power suddenly when the machine is in normal smoke condition.
  • Page 22: Maintenance

    Maintenance Before doing maintenance, please make sure that the power is cut, the power cord is unplugged, and the machine itself has cooled down. The maintenance must be done by qualified person. 1. The fluid is not allowed to get dirty. Be sure to always clean or replace the caps on the tank (Replace the caps on the tank directly. This kit includes quick connector, cap, pipe and filter) and tight the cover of the haze machine tank immediately after filling.
  • Page 23: Product Specification

    Product Specifications Model No. MYSTYQUE 400 DMX Heater Power 450W Consumption 465W DMX512 CH. 1CH, 2CH, or 4CH • Timing Fogging Built-in Function • Continuous Fogging Fuse (100V, 120V) 250V 6.3A Fuse (230V, 240V) 250V 4A Display LED Screen Tank (liters) Fog Output (cu.ft/min)