Ratek WB 000D Series User Manual

Heated digital water bath

Advertisement

Ratek WBx000D Series Water Bath - User Manual
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
User Manual
Heated Digital Water Bath
Applicable Models : WB200D, WB500D, WB1100D, WB1700D
Version: 1.0 – 29/02/2016
English
www.ratek.com.au
60 Wadhurst Dve, Boronia, Victoria 3155, Australia - P: +613 9887 2161 - F: +613 9887 2163 - E:
sales@ratek.com.au
© All Rights Reserved
Made in Australia, User Manual printed in Australia
Changes without prior notification reserved
Errors and omissions excepted.
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Page 1 of 21

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WB 000D Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Ratek WB 000D Series

  • Page 1 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ User Manual Heated Digital Water Bath Applicable Models : WB200D, WB500D, WB1100D, WB1700D Version: 1.0 – 29/02/2016 English www.ratek.com.au 60 Wadhurst Dve, Boronia, Victoria 3155, Australia - P: +613 9887 2161 - F: +613 9887 2163 - E: sales@ratek.com.au...
  • Page 2 Ensure that you have received all items outlined below before proceeding. If you have not received all components in the supplied carton, please re- pack the carton and notify a Ratek Service representative immediately. Contact details are provided in the section of this User Manual titled “Ratek Service Contact Information”...
  • Page 3: Table Of Contents

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ TABLE OF CONTENTS PAGE Cash Bo INTENDED USE ......................................4 Suitable Articles For Use With This Water Bath............................4 Unsuitable Articles For Use With This Water Bath ............................. 4 Suitable Environments For The Water Bath............................... 4 General Operation....................................
  • Page 4: Intended Use

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Intended Use This water bath is intended for the purpose of heating water only. The operator may load a suitable article onto the mesh platform for the purpose of controlled temperature application. The water bath is intended for use with tap water or filtered water only.
  • Page 5: Safety Labels And Markings

    • Important : If you have any concerns or questions relating to operator or user safety, please contact the appropriate Ratek Service department before installing and operating the unit. Contact details are provided in this User Manual.
  • Page 6: Operating Procedures

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Operating Procedures You must take the time to familiarize yourself completely with the following operating procedures before installing or operating the water bath in order to achieve the best performance and maximum attainable user safety.
  • Page 7: Safety Warnings

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Safety Warnings Throughout this User Manual, specific warnings will be supplied which relate to the current operation being referred to. These warnings are supplied in addition to the main warning labels affixed to the product and the key points outlined in the section of this User Manual titled ‘Operator Responsibility –...
  • Page 8: Preparation & Installation

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ CAUTION Always work above the level of the water bath to avoid spillage of dangerously hot water. At no point should the user, operator, animal or any other perishable object be situated directly beneath the water bath.
  • Page 9 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ strain whatsoever on the lead, socket or plug. The water bath should not be plugged into any double-adapter, power board, or power point splitter of any kind but instead directly into a correctly earthed wall mounted power socket.
  • Page 10: Using The Water Bath

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ If the water level falls below this minimum level during operation, the water bath should be powered off, disconnected from the mains electrical supply and the water level topped up with cold water. Be aware that this will result in the rapid decrease in the water bath water temperature and the effect of this in relation to the current procedure being carried out must be considered.
  • Page 11 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Switching On The Water Heating CAUTION Ensure you have filled the water bath to at least the minimum required level before switching on power to the heating system. Failure to do so may create a hazardous situation that can cause burns, scalding and create a fire risk. Ensure the mesh platform is fitted at all times during operation.
  • Page 12 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ CAUTION Temperatures above 50 degrees are sufficient to cause steam and are also capable of causing burns or scalding. Exercise extreme care paying particular attention to steam and splashing of water when the water bath is operating at these high temperatures, particularly whilst loading and unloading, containers, racks or accessories.
  • Page 13 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ CAUTION Although the heating system may now be inactive, the residual heat in the heating element may be sufficient to cause serious burns or scalding. The residual water temperature may also be sufficient to cause burns or scalding.
  • Page 14 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ - Important: Using a soft dry cloth, dry around the control panel and rear power inlet socket if this has become wet. - Dry your hands before operating any electrical equipment.
  • Page 15: Routine Cleaning And Maintenance

    Ratek and the manufacturer are consulted prior to decontamination or cleaning being undertaken if there is any doubt about the compatibility of decontamination or cleaning agents with parts of the water bath or with any materials contained in it.
  • Page 16 Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ - Once the water bath is clean, use a soft dry cloth to dry all surfaces of the water bath paying particular attention to any controls or switches. - Re-fit the mesh platform.
  • Page 17 User Manual labeled “Filling The Water Tank”. This will help to maintain the working life of the heating element. - If the over-temperature cutout has failed to operate, contact Ratek using the contact details provided in the section of this User Manual titled “Ratek Service Contact Information”.
  • Page 18: Technical Specifications

    Ratek WBx000D Series Water Bath - User Manual ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Technical Specifications Temperature Controller Digital PID using custom programmed microcontroller Temperature Sensor Thermistor Temperature Range Ambient +5° to 99.9°C (minimum 28°C) Safety - Manual reset independent over temperature cut out - Fail safe thermal fuse...
  • Page 19: Ratek Service Contact Information

    Ratek Service Contact Information Ratek are here to assist you in getting the most from your Water Bath. Our friendly staff can you assist you at any stage of the product lifecycle. If you have any concerns or questions regarding the operation of your Water Bath, please contact us.
  • Page 20: Warranty Conditions

    ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Warranty Conditions This Ratek product is covered by a 3 year parts and 12 months labour return-to-base warranty effective from the date of purchase. The product is manufactured in Melbourne, Australia. The warranty is offered by Ratek Instruments Pty. Ltd. located at 60 Wadhurst Drive, Boronia, Victoria, Australia 3155, phone number +613 9887 2161.
  • Page 21 Contact the supplier from where the equipment was purchased. If this is not possible, please contact Ratek Instruments either via email to service@ratek.com.au, or phone on +613 9887 2161 during business hours AEST. You may be referred to a local repair agent for service.