General Guidelines For Oil Change Intervals For Mobile Use - TAMROTOR Tempest E3 Operating Instructions Manual

Table of Contents

Advertisement

3.8.3 General guidelines for oil change intervals for mobile use

For recommended oil change intervals, please see the table below.
Running temperature of
the compressor
70–87°C
88–92°C
≥ 93°C
Operating temperature of the compressor can be seen in temperature gauge.
Specific AEON lubricants are recommended for use in this equipment. Other lubricants will cause:
shortened life time of oil filter, oil separating cartridges and oil
varnishing and blockage of oil circuit
increased oil consumption
excessive oil carryover and compressor damage
Do not mix different types of oil
Note! If wrong oil type has been used or oil circuit is varnished, please contact an authorized distributor of Gardner
Denver for oil circuit cleaning instructions.
12
Recommended oil change intervals
AEON 3000 oil change interval
500 hours
500 hours
300 hours
3. Maintenance instructions
AEON 9000 SP oil change
interval
1 000 hours
1 000 hours
500 hours