Error Code H1-06 Failure Detection Procedure - Denon AVR-S950H Series Service Manual

Integrated network av receiver
Hide thumbs Also See for AVR-S950H Series:
Table of Contents

Advertisement

3-4. Error Code H1-06 failure detection procedure

Checking device.
[U1026 :
ADV8003]
Check the power supply voltage.
Check item(3-4.1.).
Check the power supply volt-
age. :
Does the power supply voltage of the GUI [U1026]
indicate the appropriate voltage (1.8V, 3.3V)?
The test points are as follows.
1.8V
3.3V
3.3V
C1574
U1026
YES
GUI [U1026] is faulty.
Replace with a new device.
Recheck from
check item (3.1.).
If it does not work, replace the PCB.
NO
Check item(3-4.2.).
Check the power supply volt-
age. :
Check the power supply components
[U1069,
U1077] on the substrate and peripheral pattern.
If there is no problem, remove the GUI [U1026]
from the substrate and measure the voltage at
the test point of
check item
(3-4.1.).
Is the voltage correct (1.8V or 3.3V)?
YES
NO
The power supply circuit is faulty.
Replace the PCB.
Checking the reset waveform.
Check item(3-4.3.).
Checking the reset :
Check the CPU.
Is the waveform of the TP near the GUI [U1026] correct (like the one
shown in the diagram) when the power is turned on?
RESET
U1026
YES
NO
Check the reset circuit between CPU [U1018] and GUI [U1026].
If there is no problem, the GUI [U1026] is faulty.
Replace with a new device.
Recheck from
check item (3.1.).
If it does not work, replace the PCB.
98
10ms
10ms
Example of the waveform to be checked
Voltage scale:1.0V/div
Time scale:20ms/div
Go to next page.