Download Print this page

Error Codes - GE WCVH4800K0WW Service Manual

Advertisement

WIRE DRAWING

ERROR CODES

Error
Description
Action
Code
E00
no errors
4E
Water valve
• Check whether the faucet is closed, the water supply has
problem
been suspended or is frozen.
• Check whether the filter net in the water supply hose
connector is clogged by dirt.
• Check whether the cold water is connected.
The display will show 4E when the hot water only is connected.
5E
Drain pump
• The water does not drain due to a clogged drain hose.
problem
• Check whether the drain hose is frozen.
• Clean the filter of debris.
• Check integrity of pump motor. Replace if necessary
OE
Overflow level was
• Check valve for any signs of leaks.
reached
• Check integrity of water level sensor. Replace if necessary.
HE
Heater relay error • Replace the main pcb.
HE1
Heater problem
• Check integrity of main pcb. Replace if necessary.
1E
Pressure sensor
• Check integrity of pressure sensor. Replace if necessary.
error
LE
Leakage error
• Check integrity of tub.
9E1
Under voltage
• Measure AC outlet voltage; ensure correct range(120V to
error
132V AC)
9E2
Over voltage error
• Check electrical connections at the motor drive.
• Check harness integrity between main control and motor drive.
• Unplug the unit, wait 30 seconds and restart the unit.
• If the fault persists and re-appear, replace the main pcb.
• If the fault persists and re-appear, replace the trans
reactor or harness.
• If the fault persists and re-appear, replace the motor drive.
3E1
Motor start up
• Measure AC outlet voltage;ensure correct range(120V to
failure
132V AC)
3E2
Over current error
• Check electrical connections at the motor drive.
3E3
Hall sensor error
• Check harness integrity between main control and motor drive.
(input the hall
• Unplug the unit, wait 30 seconds and restart the unit.
sensor under 30 in
• If the fault persists and re-appear, replace the motor drive.
the running state)
• If the fault persists and re-appear, replace the main pcb or harness.
3E4
IPM over heating
• Check integrity of main pcb. Replace if necessary.
error
tE
Water thermistor
• Check integrity of thermister. Replace if necessary.
error
dE
Door open error
• The door is not close.
- Please close the door again as the until will not function
correctly when the door is left open
• Check the door DC switch. Replace if necessary.
2
dE1
Door lock error
dE3
Door un lock error • The door is not close.
bE2
Button error
AE
Communication
error between
Main and Sub PBA
SF
System Failure error • Replace main PBA.
DE2
Door Protection
SERVICE MODE SELECTIONS
1. t01 Software version number test (UI, MC)
Check the software version.
2. t02 Error codes
Check for any error codes reported by the controls.
3. t03 User interface test
Verifies all LEDs operate correctly.
4. t04 Water valve and dispenser test
Verifies the dispenser motor works and can locate all 4 dispensers positions.
5. t05 Water level sensor test
Fills to overflow water level, then pumps out water.
6. t06 Drain Pump test
Test drain pump.
7. t07 Heater and Thermistor test
Test the heater and thermistor. The estimated temperature by fahrenheit is
displayed to SSD.
8. t08 Tumble test
Verifies washer tumbles (i.e., Wash Cycle).
9. t09 Spin test
Verifies washer spins. Note: No out of balance detection will be performed
here, so the washer will spin up regardless of the out of balance that is
placed in the drum.
175D6576P001
Pub No 31-16589
• The door is not close.
- Please close the door again as the until will not function
correctly when the door is left open.
• If the fault persists and re-appear, replace the door lock switch.
- Please close the door again as the until will not function
correctly when the door is left open.
• If the fault persists and re-appear, replace the door lock switch.
• If the fault persists and re-appear, replace the main pcb.
• Check the button operation.
• If the fault persists and re-appear, replace the sub pcb.
• Check the integrity of the wiring between main and sub pcb.
• Clear the fault and run the cycle. If fault persists and re-
appears, replace the main pcb.
• The door is on and off frequently by pushing the start
button in the short time.
MODEL NUMBERS
WCVH4800K0WW
Printed in Korea
Code No.:DC68-02670A

Advertisement

loading