5. OPERATION OF ELECTROMAGNETIC VALVES AND AIR BAGS
Air massage is operated driving the Pump unit x 1pc, 3-way 3-roll electromagnetic valve, and 3-way 4-roll
electromagnetic valve.
1.
When the operation stops, the Pump and all the Electromagnetic valves are OFF.
2. While the Reclining lift motor and the Ottoman lift motor operates, the control of air stops.
(Air is in the ventilation.)
operates controlling the air.
3. When in the operation by the Controller Off/on switch, and the Electric reclining lift and the Electric
ottoman lift are operated, the Pump stops.
However, when the leg stretch operates, the Lift motor
(The air pressure is maintained.)
- 8 -