Installer
To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.
3/8" O.D. UNPLATED
1/4" O.D. TUBE
COPPER TUBE CONNECT
WATER INLET
COLD WATER SUPPLY
TO COOLER
NOTE: WATER FLOW
DIRECTION
FIG. 1
Model: EDFPW210C
IMPORTANT
BUILDING WATER INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 2
PAGE 1
97014C (Rev. E - 2/04)

Advertisement

loading

Summary of Contents for Elkay EDFPW210C

  • Page 1 Installation/Care/Use Manual Model: EDFPW210C Composite Non-Refrigerated Fountains Installer To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.
  • Page 2 WARNING: WALL MOUNTING SURFACE MUST BE SMOOTH AND EVEN. DISTOR- TION TO BACK PANEL DUE TO ATTACHMENT TO AN UNEVEN SUREFACE WILL RESULT IN DAMAGE AND/OR BREAKAGE OF THE BACK PANEL. CARE AND MAINTENANCE OF ELKAY COMPOSITE FOUNTAINS 97014C (Rev. E - 2/04) PAGE 2...
  • Page 3 This page left blank intentionally. 97014C (Rev. E - 2/04) PAGE 3...
  • Page 4 TROUBLE SHOOTING & MAINTENANCE Orifice Assy: CAUTION: Do not file or cut orifice material. Stream Regulator: Actuation of Quick Connect Water Fittings: 5, 7 SEE FIG. 5 NOTE: When installing replacement bubbler, tighten nut (item 22) Only to hold parts snug in position.