Download Print this page

Viking BLK-1A Technical Practice page 3

Line status strobe light kit

Advertisement

B. Mounting the LDB-2 Control Module
The control module is designed to be wall mounted using either screws
or the included foam tape.
Step 1. Remove the cover from the control module.
Step 2. Mount the unit on a wall, using either screws or the included foam
tape. Make sure there is easy access to the internal terminal
block. The internal board of the control module can be rotated
exposing the two mounting holes in the chassis.
Step 3. Once mounted, swing the board back into position and attach wires.
Step 4. Replace cover making sure wires protrude through rectangular wire
pass-through.
Note: For information on installing the BLK-1A with the E-1600-20A see
Other Applications.
C. Configuring the BLK-1A for Ring Indication Only
Turns on the strobe light and pro-
vides an auxiliary contact closure
during ringing only.
D. Configuring the BLK-1A for Both Ring and Loop Indication
Turns on the strobe light and pro-
vides an auxiliary contact closure
during ringing and when the phone
is in use.
P
r
o
g
r
a
m
m
P
r
o
g
r
a
m
m
A. Adjustable Relay Closure Time Out
The time out POT (see diagram to the right) can be adjusted from 2 to 6 seconds.
Turn the time out POT counter clockwise to decrease the closure time. Turn it clock-
wise to increase the closure time. When monitoring for ring, turning the time out POT
fully clockwise will allow the relay closure to be maintained (strobe will continue flash-
ing) during the entire off time of the ring signal. When monitoring for loop, the relay
closure will be maintained while off-hook and will time out following an on-hook (strobe
will continue to flash until time-out occurs).
B. Relay Contact Selections
The auxiliary relay contact located at terminal pins 5 & 6 can be used to control other
equipment. It can be set for normally open (N/O) or normally closed (N/C) by reposi-
tioning JP1 (see diagram to the right). Note: JP2 should be left in the normally open
position (N/O
Auxiliary relay contact set to normally open (N/O).
Auxiliary relay contact set to normally closed (N/C).
Incoming
Phone Line
Incoming
Phone Line
Phone
(not included)
i
n
g
i
n
g
) for controlling the strobe light.
12V DC
Adapter
(included)
1
2
Auxiliary Contact Output
12V DC
Adapter
(included)
1
2
LDB-2 Control Module
MODEL: LDB-2
Control Module
(included)
Wire Nuts
(included)
3
4
5
6
7
8
9
10
Black
(-)
(+)
Red
20 Feet of Wire (included)
Control Module
(included)
Wire Nuts
(included)
3
4
5
6
7
8
9
10
Black
(-)
(+)
Red
20 Feet of Wire (included)
Auxiliary Contact Output
Time Out
JP2
JP1
Wire Pass-
Through
Mounting
Hole
Rear View of the
Strobe Light
(included)
Black
(-)
(+)
Red
Rear View of the
Strobe Light
(included)
Black
(-)
(+)
Red

Advertisement

loading