4.3.5 Media Sensor Calibration (For the Gap Sensor)

1. Turn off the printer.
2. Press and hold the Feed/Pause Button, and then turn on the printer.
3. Release the button after the green/amber LED flashes five times and the LED is lit in
red/amber.
Note
The LED color will change as follows:
Amber  red (5 times)  amber (5 times)  green (5 times)  green/amber (5 times) 
red/amber (5 times)  green (lit)

4.3.6 Skip the AUTO.BAS program

The user can upload the AUTO.BAS program to the printer's flash memory so that it can be run
automatically at startup.
To prevent the AUTO.BAS program from running at startup:
1. Turn off the printer.
2. Press the Feed/Pause Button, and then turn on the printer.
3. Release the button when the LED is lit in green.
Note
The LED color will change in the following order:
Amber  red (5 times)  amber (5 times)  green (5 times)  green/amber (5 times) 
red/amber (5 times)  green (lit)
4. The printer will start without running the AUTO.BAS program.
32