Chapter 4 Adjusting the IndES™ Module
Air Pressure
!
WARNING
!
WARNING
The IndES™ Module is designed to be operated at 80 PSI [ .55 MPa] 5F
Increasing the pressure greater than the recommended MAX air pressure may:
Cause a dangerous condition to the operator
•
Damage the IndES™ Module
•
Void the manufacturer's warranty
•
An air pressure regulator is provided with the IndES™ Module Assembly and is factory set to
the required air pressure. The pressure regulator will reduce the input air pressure to the
recommended operating air pressure. Verify the reading on the air pressure regulator's dial
which
indicates
the
operation.
Air Pressure
Regulator
MAXIMUM AIR PRESSURE 80 PSI (.55 MPa)
Module needles are sharp. Use caution when removing
and replacing needles and during operation.
Discard needles that are damaged or have punctured
the skin
3
/min [.63 M
operating pressure prior to
3
/min]
10