Silas Kainge
May 9, 2025

the motor does not want to start

1 comments:
Mr. Anderson
May 19, 2025

The TRADEair MCFRC103 motor may not start due to the following possible causes:

1. Fault in the power line or insufficient voltage – check the line.
2. Power wire is too thin or too long – replace the wire.
3. Faulty pressure switch – repair or replace.
4. Fault in the motor – repair or replace.
5. Sticking of the main compressor – check and repair.
6. Inner thermal protector on the motor has cut off – turn off the power, wait 10–15 minutes for the motor to cool, then restart.

This answer is automatically generated