Download Print this page

Tech Lighting 700AT300TR Installation Instructions page 3

12v single feed recessed magnetic transformer

Advertisement

Connect the 120 Volt Wires
3A
120 VOLT
TERMINAL BLOCK
HOT POWER LINE WIRE
NEUTRAL POWER LINE WIRE
1
Install the 120 volt power line wires to the transformer.
Insert the hot power line wire inline with the black
2
transformer wire into the terminal block and tighten the
screw.
Insert the neutral power line wire inline with the white
3
transformer wire into the terminal block and tighten the
screw.
Ground the transformer housing in accordance with
4
local electrical codes.
4
2
3
1
Check the System
4A
3
SCREW
3
COVER
1
After installing the entire low voltage system, if the
lamps have low intensity, then measure the voltage at
the fixture closest to the power feed contacts with a
voltmeter. The system must be at least 80% loaded
and the voltmeter should read between 11V - 12V
~AC. If the voltage does not fall in this range, call
Tech Lighting "Technical Support" at 847-410-4606.
Operate the system for five minutes. On the low
2
voltage side, all electrical connection spots should be
cool to the touch. If a connection is hot to the touch,
retighten the connection and check to ensure that the
temperature decreases.
3
Place the transformer cover and tighten all four
provided Phillips screws on the front.
3
3
3

Advertisement

loading