6.
MAINTENANCE
IMPORTANT: Only fully qualified personnel should attempt maintenance or repair.
6.1.
When the jack is not in use, the saddle must be in the lowest position to minimise ram and piston corrosion.
6.2.
Keep the jack clean and wipe off any oil or grease. lubricate all moving parts with acid free oil.
6.3.
The oil cylinder is a sealed unit and must not be accessed. For service contact your authorised dealer.
F
WARNING! Only a good quality Jack oil, such as SEALEY HYDRAULIC JACK OIL must be used, DO NOT use brake fluid.
6.4.
Before each use, follow the pre-check list to ensure components are not damaged, malfunctioning or has a missing part (see Section
4). If any suspect item is found remove jack from service and take necessary action to remedy the problem.
DO NOT use the jack if believed to have been subjected to abnormal load or shock. Inspect and take appropriate action.
6.5.
Periodically check the pump piston and piston rod for signs of corrosion. Clean exposed areas with a clean oiled cloth.
IMPORTANT: NO RESPONSIBILITY IS ACCEPTED FOR INCORRECT USE OF THE JACK.
Hydraulic products are only repaired by local service agents. We have service/repair agents in all parts of the UK. DO NOT RETURN JACKS
TO US. Please telephone 01284 757500 to obtain address and ‘phone number of your local agent. If Jack is under guarantee please contact your dealer.
De-commissioning the jack: Should the jack become completely unserviceable and require disposal, draw off the oil into an approved container
and dispose of the jack and the oil according to local regulations.
7.
TROUBLESHOOTING
IMPORTANT! Although the following may identify a problem, in most cases the problem must be resolved by your authorised service agent.
PROBLEM
Jack will not lift
Jack will only lift halfway
Raised load will not hold
Poor lifting
Declaration of Conformity We, the sole importer into the UK, declare that the product listed below
EEC standards and directives.
Telescopic Vehicle Transmission Jack
Model 1250GTA
98/37/EC Machinery Directive
(S.I. 1992/3073)
93/68/EEC CE Marking Directive
NOTE:
It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this equipment
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For copy of our latest catalogue & promotions, call on 01284 757525 and leave your full name and address, including postcode.
01284 757500
CAUSE
No hydraulic oil, or defective suction valve or delivery valve
Release valve is open
Hydraulic oil low, or excess of hydraulic oil
Defective valves, or defective piston packing
Defective plunger packing
The construction file for
and may be inspected by a national authority by contacting Jack Sealey Ltd.
For Jack Sealey Ltd., Sole importer into the UK of Sealey
01284 703534
this
Signed by Mark Sweetman
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
E-mail: sales@sealey.co.uk
SOLUTION
Contact authorised service agent.
Close release valve.
Contact authorised service agent.
Contact authorised service agent.
Contact authorised service agent.