Instruction manual Hygienic Design Planetary Gearbox

8 Cleaning

8
Cleaning
GB_ 100225294 / Rev. status "004"
Only clean the gearbox while it is at standstill
Risk of injury for the cleaning personnel
o
Liquid may get into the interior because of the gearbox's rotary motion.
o
Only approved detergents may be used to ensure that the product does not
corrode or get damaged.
A high-pressure water jet (max. 26 bar) may be applied to the casing as such.
The seals (especially the radial shaft seal ring) must however be omitted from
cleaning with a high-pressure water jet to avoid damaging them.
Remove any media in contact with the seals within 20 minutes to prevent
them from getting sucked in.
Cleaning plan
Recommended cleaning plan with the tested detergents (see Chapter 4.5):
Rinsing with water (40°... 50°C)
Rinse at low pressure. From the top down in direction of the drain. Clean the drain.
Foam cleaning (cold up to 40°C)
Lathering from the top down.
Alkaline: P3-topax 66 (2-5%, daily for 15 min)
Acidic: P3-topax 52 (2%, 15 min when necessary)
Disinfection (40°... 50°C)
Spraying with water at low pressure. From the top down.
Spray disinfection: P3-topax 990 (1-2%, 30-60 min when necessary)
Foam disinfection: P3-topactiv OKTO (1-3%, 10-30 min when necessary)
Dry cleaning (compressed air)
It is not permitted to apply compressed air directly to the sealing elements.