Installation Instructions for
Revel Pathway
G
ENERAL RODUCT NFORMATION
P
I
This product is suitable for wet locations.
12VAC input only.
If using Tech Lighting magnetic transformers, this product be
dimmed with a low-votage magnetic dimmer. For all other
transformers, consult with the manufacturer for compatible
dimmers.
WARNING – Risk of Electric Shock. Install all luminaires
10 feet (3.05 m) or more from a pool, spa, or fountain.
Unit low voltage cable is to:
a) be protected by routing in close proximity to the
luminaire or fitting, or next to a building structure such
as a house or deck;
b) not be buried except for a maximum 6 inches (15.2
cm) in order to connect to the main low voltage cable;
and
c) have the length cut off so that it is connected to a
connector within 6 inches (15.2 cm) from a building
structure, a luminaire, or fitting.
Prepare the Fixture
1A
1
1
BASE PLATE
Loosen
(Do Not Remove)
1
base with the provided Allen wrench and remove the
base plate.
INSTALLATION OPTIONS:
For Stake Install - see section 2
For Concrete and
other Hard Surfaces
OUTDOOR
:
SET SCREW
1
ALLEN
WRENCH
1
the four set screws on fixture
- see section 3
CAUTION RISK OF FIRE
This product must be installed in accordance with
the applicable installation code by a person familiar
with the construction and operation of the product
and the hazards involved.
Use minimum 90°c supply conductors.
Install the Fixture using a Stake
2A
STAKE BOLT
STAKE
Attach the stake to the base plate by tightly screwing
1
down the provided stake bolt through the center hole
of the base plate and the stake.
Reattach the base plate assembly to fixture and tighten
2
down the set screws (reversal of Section 1A).
1
920OAREVEL
700OARVL_
-
BASE PLATE
1.1