Calibrating The 320-E With The R2 Actuator (For Use With Propress Xl Rings); Calibrating The 320-E With The V1 Or V2 Actuator (For Use With Propress Rings Or Propress Xl-C Rings); Preparing The Connection - RIDGID ProPress Series Operator's Manual

Fitting system
Table of Contents

Advertisement

Available languages

Available languages

3. Depress ON/OFF button on display panel one time to
turn tool on. The audible alarm should beep once and
all three light emitting diodes (LED's) will blink once.
Then, the green LED should be blinking indicating cal-
ibration is required.
Tool will automatically go into "sleep" mode if left
unused for ten (10) minutes. To "wake up" tool, it is
necessary to once again depress the ON/OFF button
on the top display panel.
4. Complete one tool cycle with an empty scissor style
jaw set (no fitting in jaw). Green LED should now
glow solid indicating tool is properly calibrated. The
tool is now ready to begin pressing fittings. The tool
will remain calibrated as long as jaw set is installed
unless tool is left idle for longer than sixty (60) minutes.
In this instance, which will be indicated by blinking
green LED after tool is turned back on, the calibration
process must be repeated.
Every time jaw set or actuator is replaced (jaw mount-
ing pin is opened), the calibration process should be
repeated to allow proper jaw closure detection.
Calibrating The 320-E With The R2
Actuator (For Use With ProPress XL
Rings)
1. Insert fully charged battery into the handle of the
320-E press tool.
2. Depress ON/OFF button on display panel one time to
turn tool on. The audible alarm should beep once and
all three light emitting diodes (LED's) will blink once.
Then, the green LED should be blinking indicating cal-
ibration is required.
Tool will automatically go into "sleep" mode if left
unused for ten (10) minutes. To "wake up" tool, it is
necessary to once again depress the ON/OFF button
on the top display panel.
3. Complete one tool cycle with an empty R2 Actuator
(no press ring attached). Green LED will continue to
blink but the ram position detection feature is now dis-
abled. Due to the design of press rings, it is not pos-
sible to detect jaw closure since the rings never fully
close. The tool is now ready to begin pressing
ProPress XL fittings. The tool ram position detec-
tion will remain disabled as long as the ring actuator
is installed unless tool is left idle for longer than sixty
(60) minutes. In this instance, after the tool is turned
back on (by depressing the ON/OFF button on display
panel) the calibration process must be repeated.
Every time R2 Actuator is replaced the calibration
process should be repeated to disable the ram posi-
tion detection feature.
Calibrating The 320-E With The V1 Or
V2 Actuator (For Use With ProPress
Rings Or ProPress XL-C Rings)
1. Make sure the correct actuator (V1 or V2) is installed
in the 320-E.
2. Insert fully charged battery into the base of the 320-E
handle.
3. Depress ON/OFF button on the display panel one
time to turn tool ON. The audible alarm should beep
once and all three light emitting diodes (LED's) will
blink once. Then, the green LED should be blinking
indicating calibration is required.
Tool will automatically go into "sleep" mode if left
unused for ten (10) minutes. To "wake-up" tool, it is
necessary to once again depress the ON/OFF button
on the top display panel.
4. Open the Actuator and engage onto the appropri-
ate Press Ring for the application.
5. Complete one tool cycle with the desired Actuator and
Ring (no fitting in press ring). Green LED should now
glow solid indicating tool is properly calibrated for
the selected Actuator and Ring combination. The
tool is now ready to begin pressing fittings. The tool
will remain calibrated as long as actuator is installed
unless tool is left idle for longer than sixty (60) minutes.
In this instance, which will be indicated by blinking
green LED after tool is turned back on, the cali-
bration process must be repeated.
6. If it is desired to change the size of fitting being
pressed and use a different size Ring that works with
the Actuator which is already installed in the tool, it is
necessary to recalibrate the new Ring/Actuator com-
bination. To accomplish this, the attachment mounting
pin must be partially opened and the fully inserted
again. This action will erase the previous calibration
setting. The green LED should now be blinking, indi-
cating the tool is ready for calibration. Next, repeat step
5 for the new Ring/Actuator combination.

Preparing The Connection

NOTICE
low the fitting manufacturers specific installation instruc-
tions. Failure to follow the fitting manufacturer's installation
instructions may lead to an improper press connection and
cause leaking connections and property damage.
Ridge Tool Company
ProPress
®
Fitting System
These are generalized instructions. Always fol-
7