PERSONAL PROTECTION EQUIPMENT (PPE)
RESPIRATORY
PROTECTIVE
PROTECTIVE
PROTECTION
GLOVES
BOOTS
IMPORTANT - CONDUCT A RISK ASSESSMENT
Before you commence any work at your chosen work area, you should
undertake some preliminary hazard identification and risk control
precautions. Ideally more than one person should do this. This is
undertaken by:
1.
Physically inspecting the work site
2.
Reviewing the best way/job steps required to complete the task
3.
Reviewing the Safe Work Information supplied with the equipment
4.
Reviewing other reference documentation and expert advice.
The hazard identification and control process steps are defined as:
1.
Identify the Hazards (eg. 240V power drill use around wet areas)
2.
Assess the Risk (multi earth paths - possible electrocution)
3.
Select the Control Measure (e.g. dry the area; use an RCD; use a
cordless drill etc)
4.
Re-assess the Risk (risk of electrocution now negligible). This is
undertaken to ensure that the risk control measures adopted have not
introduced any new risks to the work area.
SAFETY INFORMATION
Take the influences of the surrounding area into account. Do not
expose the appliance to rain or snow and do not use it in damp or wet
conditions. Do not use the appliance where there is a risk of fire of
explosion.
Use the right appliance for the job. Do not use the appliance for
purposes for which it was not intended. Use it only as directed and
when in faultless condition.
Do not abuse the supply cord and/or the hose. Never use the supply
cord or hose to carry or pull the appliance and do not pull the supply
cord when unplugging. Damaged supply cords increase the risk of
electric shock.
Keep the supply cord and hose away from heat, oil, sharp edges or
moving parts.
Check the appliance and its accessories for any damage. Guards,
safety devices and any slightly damaged parts must be checked
carefully to ensure that they function faultlessly and as intended.
Check that moving parts function correctly without sticking and that no
parts are damaged. All parts must be
fitted correctly and fulfill all conditions necessary for correct operation
of the appliance. Damaged guards, safety devices and other parts
must be repaired or replaced properly at an authorized service center
unless otherwise indicated in the operating instructions.
DIAMOND DRILLING VACUUM PUMP
SAFETY SHEET
(Hilti DD VP-U)
PLEASE READ THIS GUIDE CAREFULLY
BEFORE OPERATING THE EQUIPMENT
HELP AND SUPPORT
If the unit does not operate correctly or you are unhappy with its
performance, return it to Asset Construction Hire for an exchange,
or phone for assistance. Do not attempt repairs yourself.
Asset Construction Hire
Phone:1300 361 383 or email: office@assethire.com.au
OPERATION MANUAL
A PDF of the full Operation Manual is available at:
www.assethire.com.au/manuals-specs-safety-sheets/
and must be read before using the equipment.
BEFORE OPERATING THE EQUIPMENT:
Read this Safety Sheet and any other information provided with the
equipment, including instructions, decals and operation guidelines.
Check that you understand how and when the use the equipment,
and know how to operate it safely.
Ensure that it is only used according to the manufacturers and hirer's
instructions, and only for work that is compatable with its technical
limitations.
Operate in a clear work area free from nonessential persons, children,
animals or hazards.
Ensure that you have a secure footing and clear access and egress to
the work area while on the job.
Do not operate any equipment if you are tired or suffering any medical
condition, or if under the influence of drugs or alcohol which may
cause lethargy or dangers to yourself or others.
Do not use faulty equipment. If in doubt contact Asset Construction Hire.
During operation, protect the appliance and hose from the effects
of external influences which could result in damage to the water
separator or hose.
Observe the operating instructions for the diamond coring machine
used.
Avoid restriction or blocking of the hose, e.g. pinching, kinking or
entry of dirt.
Keep the ventilation slots on the pump clean and unobstructed.
Ensure adequate free space at the air exit in order to avoid
overheating of the appliance.
Never allow the pump to stand in water.
The pump should stand on a dry horizontal surface when in operation
and should be secured to prevent possible movement.
The vacuum will be maintained for a short time after failure of the
electric supply or malfunction of the appliance. Should this occur, stop
working immediately and check the pressure gauges on the pump
and vacuum base plate. Secure the workpieces to prevent falling.
Do not modify the appliance or tamper with its parts.
Use only genuine Hilti spare parts.
Empty the water separator each time before transporting the pump.
Ensure that the workplace is well lit.

Advertisement

loading

Summary of Contents for Hilti DD VP-U

  • Page 1 Do not modify the appliance or tamper with its parts. • Check that moving parts function correctly without sticking and that no • Use only genuine Hilti spare parts. parts are damaged. All parts must be • Empty the water separator each time before transporting the pump.
  • Page 2 After a short time, the pressure gauge should indicate a pressure In these operating instructions, the designation within the green area. Always keep these operating in- “the appliance” always refers to the DD VP-U. structions together with the appli- ance. Parts, operating controls and indicators 1...