Mace EchoFlo Series Quick Start Manual

Advertisement

Quick Links

MACE USA LLC
PO Box 7144
Overland Park, KS 66207
United States of America
Ph: 888 440 4215 Fax: 888 440 6999
Email: sales@maceusa.com
www.maceusa.com
Measuring & Control Equipment (MACE) P/L
PO Box 911, Pennant Hills
Q u i c k
S t a r t
G u i d e
NSW 1715, Australia
Ph: (02) 9658 1234 Fax: (02) 9651 7989
Email: sales@macemeters.com
www.macemeters.com
www.macemeters.com
Part No. 825-320 Rev. 1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EchoFlo Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Mace EchoFlo Series

  • Page 1 United States of America Ph: 888 440 4215 Fax: 888 440 6999 Email: sales@maceusa.com www.maceusa.com Measuring & Control Equipment (MACE) P/L PO Box 911, Pennant Hills Q u i c k S t a r t G u i d e...
  • Page 2 3. Double click the EchoCal icon and communication with the EchoFlo connected to your PC will commence. The following EchoCal dialogue box will appear. A typical flow measuring application in a partially full, closed pipe is shown below. The MACE EchoFlo (mounted on the top of the pipe) measures the depth and a MACE Doppler sensor (2” insert) measures velocity. Together, these two sensors are connected to a Series 3 FloPro that calculates, records and displays the resultant flow rate.
  • Page 3 “Clear Screen”. 2. All configuration settings must be selected IMPORTANT: before you can continue. The recommended settings for connection to a MACE Series 3 1. Do not mount at an angle device are shown on the right. 2. Liquid should NEVER enter the deadband 3. Mount at least 2” from the side wall 3.
  • Page 4 ECHOFLO POWER (RED) ECHOFLO WIRING TO FREQUENCY INPUT ON TERMINAL STRIP NOTE: MACE recommends using the EchoFlo in it’s Frequency Stand Pipe: ECHOFLO GROUND (BLACK) output mode for simple configuration and calibration as ECHOFLO SHIELD (BARE WIRE) Use a stand pipe when detailed in the following sections of this guide.
  • Page 5 (a longer period may be required to record a stable reading channel. in some applications). • Add an I/O module NOTE: Refer to the relevant MACE Series 3 product manual for detailed instruction on the above steps 6. The “Configure channels” dialogue box will re-appear 2.
  • Page 6 entering Slope and Offset calculating the echoFlo Slope & Offset 1. In the “Configure The Slope and Offset values of the installed EchoFlo are dependent channels” dialogue box on the “Fill Height” as entered during the EchoCal configuration click “Edit” and the “Edit procedure. channel” dialogue box will NOTE: The following calculations are based on the EchoFlo appear.

This manual is also suitable for:

Echoflo 2.5mEcoflo 1.25m

Table of Contents