SLB分支机构设备管理器快速入门指南
电源分配器(带适配器功能)
里面有
什么
SLB Branch Offi ce Manager Quick Start Guide
WHAT'S
Accessories Included
Power Cords Included
INSIDE
Part Number
Description
Included power cords vary for kit purchased. Please see www.lantronix.com for
200.2066A
Adapter: RJ45 to DB25M (DCE)
additional inlet power cords available.
for Sun with DB25 female
SLB Part #
Power Cord Part # Power Cord Description
Quantity
SLB Branch Offi ce Manager Quick Start Guide
200.2067A
Adapter: RJ45 to DB25F (DCE)
100-120 VAC (50/60 Hz)
INSIDE
WHAT'S
Accessories Included
200.2066A
200.2069A
200.2067A
Part Number
Adapter: RJ45 to DB25M (DCE)
Adapter: RJ45 to DB9M (DCE) for
Description
for Sun with DB25 female
Adapter: RJ45 to DB25F (DCE)
some HP9000's
for Sun with DB25 male and
SLB882KIT-15P
SLB882KIT-20P
Power Cords
(50/60 Hz)
Kit
additional inlet power cords available.
Included power cords vary for kit purchased. Please see www.lantronix.com for
100-120V
100-120V
AC Voltage
Inlet cord: IEC60320/C19
Inlet cord: IEC60320/C19
Power Cord Description
Part Number
SLPP12410-01
to NEMA 5-15P (15A)
SLPP12310-01
for Sun with DB25 male and
SLB882KIT-15P
SLPP12310-01
IEC60320/C19 to NEMA 5-15P (15A)
2
Quick Start Guide
SLB
200.2070A
200.0063
ADP010104-01 Adapter: RJ45 Rolled serial, 0.1m
Linux servers
Cable: RJ45 to RJ45, Cat-5, 2m
(0.33 Ft.) for Cisco and Sun Netra
for HP9000, SGI Origin, IBM
RS6000,and PC-based Unix/
SGI Onyx
(6.6 Ft.)
Adapter: RJ45 to DB9F (DCE)
SLB8824KIT-EU
SLB8824KIT-AP
200-240V
200-240V
SLPP12A08-01
Inlet cord: IEC60320/C19
SLPP12810-01
SLPP12910-01
to Schuko (EU)
to BS1363 (UK)
Inlet cord: IEC60320/C19
IEC60320/C19 to AS/NZS
3112 (AU/NZ)
SLPP12C08-01
GB (CN)
IEC60320/C19 to CHINA/
to NEMA 5-20P (20A)
1 HARDWARE REVIEW
110-120V AC
Front View
LCD
Keypad
Device ports 1-8
500-153
USB Port
Console Port
USB Port
Cable:RJ45 Loopback
LCD
200-240V AC
Console Port
Keypad
Front View
Device ports 1-8
USB Port
some HP9000's
SLB882KIT-20P
SLPP12410-01
IEC60320/C19 to NEMA 5-20P (20A)
2
Power outlets 1-8
ports
Dual Ethernet
10/100
Secondary AC Inlet
Back View
Primary AC Inlet
Modem
Modem
Dual Ethernet
Power outlets 1-8
ports
10/100
Secondary AC Inlet
Primary AC Inlet
Back View
Modem
200.2069A
Adapter: RJ45 to DB9M (DCE) for
used in the SLB, dial-in access is possible in the event that the IP
an IP network or the Internet. Once installed on the IP network,
The SLB connects between a server or a piece of IT equipment and
of a space saving 19" 1RU design.
(HTTPS/SSL), Secure Shell (SSH), or Telnet session. If a modem is
a remote user connects to the SLB using a secure web browser
The SLB is a hybrid console manager and power manager in the form
need the female DB9 adapter (Part #200.2070A) and a standard
Cat-5 cable, both of which are supplied with the SLB.
For example, to connect a PC to the device port of the SLB, you only
SGI Onyx
200-240 VAC (50/60 Hz)
equipment is connected to one of the SLB power outlets, then
console port to perform maintenance or management tasks. If the
or PC with terminal emulation software to locally access manage-
network is unavailable. Once connected, the user has access to
the server or IT equipment's command line interface (CLI) via the
The front LCD panel and keypad allows for quick and easy network
configuration. The front panel console port allows a dumb terminal
(on/off/reboot) power control is possible.
The default communication parameters for the device ports and the
console port are:
SLB8824KIT-EU SLPP12810-01
IEC60320/C19 to Schuko (EU)
2
ports allow simple connections to serial devices using adapters and
ment functions and connected serial console devices. The device
device port, and the other end to an adapter that attaches to the
a standard Cat-5 cable. Connect one end of the Cat-5 cable to the
serial console of the target system.
state of each outlet (on/off/reboot).
source. Once connected you can remotely and securely control the
The power outlets allow your equipment to use the SLB as its power
• 9600 baud • 8 data bits • No parity • 1 stop bit • No flow control
200.2070A
Adapter: RJ45 to DB9F (DCE)
Quick Start Guide
for HP9000, SGI Origin, IBM
SLPP12910-01
EC60320/C19 to BS1363 (UK)
2
RS6000,and PC-based Unix/
SLB8824KIT-AP
SLPP12A08-01
IEC60320/C19 to AS/NZS 3112 (AU/NZ) 2
Linux servers
SLPP12C08-01
IEC60320/C19 to CHINA/GB (CN)
2
ADP010104-01 Adapter: RJ45 Rolled serial, 0.1m
SLB8824KIT-WW SLPP12810-01
IEC60320/C19 to Schuko (EU)
1
(0.33 Ft.) for Cisco and Sun Netra
SLPP12910-01
EC60320/C19 to BS1363 (UK)
1
200.0063
Cable: RJ45 to RJ45, Cat-5, 2m
SLPP12A08-01
IEC60320/C19 to AS/NZS 3112 (AU/NZ) 1
(6.6 Ft.)
SLB
SLPP12C08-01
IEC60320/C19 to CHINA/GB (CN)
1
500-153
Cable:RJ45 Loopback
1 HARDWARE REVIEW
100-120V AC
200-240V AC
Front View
Front View
Device ports 1-8
Device ports 1-8
LCD
Keypad
Console Port
LCD
Keypad
Console Port
USB Port
USB Port
USB Port
Modem
Modem
Modem
10/100
10/100
Dual Ethernet
Power outlets 1-8
Primary AC Inlet
Dual Ethernet
Power outlets 1-8
Primary AC Inlet
ports
Back View
Secondary AC Inlet
ports
Back View
Secondary AC Inlet
The SLB is a hybrid console manager and power manager in the form
For example, to connect a PC to the device port of the SLB, you only
of a space saving 19" 1RU design.
need the female DB9 adapter (Part #200.2070A) and a standard
Cat-5 cable, both of which are supplied with the SLB.
The SLB connects between a server or a piece of IT equipment and
an IP network or the Internet. Once installed on the IP network,
a remote user connects to the SLB using a secure web browser
(HTTPS/SSL), Secure Shell (SSH), or Telnet session. If a modem is
used in the SLB, dial-in access is possible in the event that the IP
network is unavailable. Once connected, the user has access to
the server or IT equipment's command line interface (CLI) via the
console port to perform maintenance or management tasks. If the
equipment is connected to one of the SLB power outlets, then
(on/off/reboot) power control is possible.
The front LCD panel and keypad allows for quick and easy network
configuration. The front panel console port allows a dumb terminal
The default communication parameters for the device ports and the
or PC with terminal emulation software to locally access manage-
console port are:
ment functions and connected serial console devices. The device
ports allow simple connections to serial devices using adapters and
• 9600 baud • 8 data bits • No parity • 1 stop bit • No flow control
快速入门指南
a standard Cat-5 cable. Connect one end of the Cat-5 cable to the
The power outlets allow your equipment to use the SLB as its power
device port, and the other end to an adapter that attaches to the
source. Once connected you can remotely and securely control the
serial console of the target system.
state of each outlet (on/off/reboot).
SLB
1 硬件评测
100-120V AC
LCD ( 液晶显示屏)
电源输出插座1-8
10/100
双以太网端口
SLB是一种复合控制台管理器和电源管理器, 采用节省空间的
19英寸1RU设计。
SLB将服务器或IT设备连接到IP网络或互联网上。 一旦安装
在IP网络上, 远程用户便可以通过安全网络浏览器 (HTTPS/
SSL) 、 安全外壳 (SSH) 或Telnet会话连接到SLB。 如果SLB中安
装了调制解调器, 那么在IP网络不可用的情况下可以通过拨号
访问。 一旦建立连接, 用户通过控制台端口可以访问到服务器
或IT设备的命令行界面 (CLI) , 进而完成维护或管理任务。 如果
设备连接到SLB的一个电源输出插座上, 那么就可以对其电源
进行控制 (开/关/重启) 。
利用前端LCD面板和数字小键盘可以方便快速地进行网络配
置。 利用前面板上的控制台端口, 可以通过一台哑终端或安装
有终端仿真软件的PC机实现本地访问管理功能, 并对所连接
的串行控制台设备进行管理。 这些设备端口允许使用适配器和
标准5类电缆与串行设备进行简单连接。 将5类电缆的一端连
接到设备端口上, 另一端连接到与目标系统串行控制台相连的
适配器上。
随附配件
件号
描述
适配器: RJ45转DB25M (DCE) ,
200.2066A
用于带DB25母头的Sun服务器
适配器: RJ45转DB25F ( DCE) ,
200.2067A
用于带DB25公头的Sun服务器和
部分HP9000服务器
适配器: RJ45转DB9M (DCE) ,
200.2069A
用于SGI Onyx服务器
适配器: RJ45转DB9F ( DCE) ,
200.2070A
用于HP9000、 SGI Origin、 IBM RS6000
服务器以及基于PC的Unix/Linux
服务器
ADP010104-01 适配器: RJ45超薄串口, 0.1米 (0.33
尺) , 用于Cisco和Sun Netra服务器
线缆: RJ45到RJ45 , 5类线,
200.0063
2米 (6.6英尺) 。
线缆: RJ45环回
500-153
前视图
设备端口1-8
键盘
控制台端口
主AC电源输入插座
副AC电源输入插座
后视图
电源线随附
所附带的电源线因购买的产品套装不同而有所差别。 请参阅
www.lantronix.com, 了解可供使用的其他电源输入线。
件号
电源线件号
SLB
100-120 VAC (50/60 Hz)
SLB882KIT-15P
SLPP12310-01
SLB882KIT-20P
SLPP12410-01
200-240 VAC (50/60 Hz)
SLB8824KIT-EU
SLPP12810-01
SLPP12910-01
SLB8824KIT-AP
SLPP12A08-01
SLPP12C08-01
SLB8824KIT-WW
SLPP12810-01
SLPP12910-01
SLPP12A08-01
SLPP12C08-01
200-240V AC
LCD ( 液晶显示屏)
USB端口
调制解调器
电源输出插座1-8
10/100
双以太网端口
例如, 要将一台PC连接到SLB的设备端口上, 您只需要DB9母
头适配器 (件号200.2070A) 和一条标准5类电缆, 两者均随
SLB一起提供。
设备端口和控制台端口的默认通信参数如下:
• 9600波特 • 8个数据位 • 无奇偶校验 • 1个停止位 • 无流量控制
电源输出插座允许您的设备将SLB作为其电源。 一旦建立连
接, 您便可以远程安全地控制每个插座的状态 (开/关/重启) 。
4
电源线描述
IEC60320/C19 至 NEMA 5-15P (15A)
IEC60320/C19 至 NEMA 5-20P (20A)
IEC60320/C19 至 Schuko (EU)
IEC60320/C19 至 BS1363 (UK)
IEC60320/C19 至 AS/NZS 3112 (AU/NZ)
IEC60320/C19 至 CHINA/GB (CN)
IEC60320/C19 至 Schuko (EU)
IEC60320/C19 至 BS1363 (UK)
IEC60320/C19 至 AS/NZS 3112 (AU/NZ)
IEC60320/C19 至 CHINA/GB (CN)
前视图
设备端口1-8
键盘
控制台端口
主AC电源输入插座
副AC电源输入插座
后视图
数量
2
2
2
2
2
2
1
1
1
1
USB端口
调制解
调器
Need help?
Do you have a question about the SLB and is the answer not in the manual?