操作提示
用这台高压电源给一台容性负载供电通常是没有问题的。
但是由于产品内部构造,有下列限制:
不可在电源的直流输出端接上任何电容去给它们充电
或放电。
根据产品型号的不同,其直流输出端允许最大容量也
不同,分别为:
1,2 kV 型号:4 mF
2 kV 型号:1 mF
4 kV 型号:250 μF
6 kV 型号:100 μF
12 kV 型号:35 μF
如果确实有需要连接更大的电容,必须在产品内部做些更
改。这个更改可按照客户要求操作,但是必须在工厂内完
成。
详情可与我们联络。
© EA Elektro-Automatik, Germany, 41747 Viersen, Helmholtzstr. 31-34, Tel. +49 2162 37850, Fax. +49 2162 16230
操作 / Operation
Notes for the operation
Operating the high voltage power supply with a capacitive
load is not unproblematic. Due to the internal construction
of the devices, following restrictions apply:
It is not allowed to connect any capacity to the DC
output, in order to charge/discharge it
The max. allowed capacity on the DC output is de-
pending on the model:
1,2 kV model: 4 mF
2 kV model: 1 mF
4 kV model: 250 μF
6 kV model: 100 μF
12 kV model: 35 μF
In case it is absolutely required to connect higher capaci-
ties, the device would have to have an internal modification
installed. This modification can be done upon request, but
only in the factory.
Please contact us for details.