Advertisement

Max Pulse
User Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Max Pulse and is the answer not in the manual?

Questions and answers

Summary of Contents for MEDICORE Max Pulse

  • Page 1 Max Pulse User Manual...
  • Page 2: Table Of Contents

    4.1.3 Power Cable Connection to the Max Pulse ................ 9 ※ Run the program of Max Pulse installed on the computer and then check if the program is running properly........................9 4.2 Caution When Installing the Program ..................9 5 Method of Measurement........................
  • Page 3: General

    GENERAL Thank you for using the Max Pulse. Please read this User’s Manual carefully before operating this equipment for proper handling and maintenance, and get familiar with all the functions and features of this equipment for safe handling and reliable performance.
  • Page 4: About User Manual

    1 About User Manual This manual contains all the information needed to operate our Max Pulse and it further provides exact information on the conditions of the patients including the measured parameter analysis. Because the chapters in the manual are constructed so that each chapter can be used independently, some contents may appear in more than one chapter.
  • Page 5: Electrical Safety And Precautions

    Keep out of the reach of children and pets to prevent them from electric shocks. 2.3 Cleaning and Maintenance. It is recommended that the body of Max Pulse and accessories should always be maintained in a clean condition.. The free repair service does not cover any damage caused by using any substances that may lead to product damages Use warm water or alcohol on a soft cloth to clean and remove dust.
  • Page 6: During The Measurement

    Remove nail varnish on left finger nail before measurement. Relax for 15~20 minutes before measurement. 2.4.4 During the Measurement Patients should not move or speak during the measurement, and breathe normally 2.4.5 Why to get different result when testing multiple times In general, a healthy person has a large change in heart rate, and conversely, a person with a disease (diabetes, myocardial infarction, arteriosclerosis, obesity, etc.) or older people has less change in heart rate.
  • Page 7: Overview

    3. Overview 3.1 Purpose of Using Max Pulse Max Pulse measures heart rate variability in a given time period and analyzes the variability to determine one’s overall health status and autonomic nerves system activity. Throughout the measurement, the levels of physical/mental stress, autonomic nerves balance and vascular aging are evaluated.
  • Page 8: Program Installation

     Insert the Installation CD into PC CD-ROM.  Click Max Pulse _General_V.x.x_Install.exe inside Max Pulse Program folder.  Max Pulse installation screen will be shown as below. (The name and version no. of .exe file can be different according to upgraded version) ...
  • Page 9: Probe Connection To The Max Pulse

     Check if power lamp light is on. ※ Run the program of Max Pulse installed on the computer and then check if the program is running properly. Note) Connect “USB TO RS232 CABLE” to the device and PC before installation of the Max Pulse program.
  • Page 10: Method Of Measurement

    5 Method of Measurement 5.1 Advice for Users Who Using Max Pulse Do not move or talk during the measurement. Do not exercise, and relax about 10 minutes in measuring room before taking measurement. Do not strain and then take regular breath. Refrain from slowly breathing during the measurement.
  • Page 11: Setup Screen

    ② Language - Select language in the combo box. - If you changed language, press SAVE button and then restart the Max Pulse program. ③ Measurement time - Select 45 sec, 3 min or 5 min in the combo box.
  • Page 12: User Registration / Edit

    F9 : Automatically comments on the result 5.2.3 User Registration / Edit ① BUTTON - When you press “NEXT” button ( ) after inserting all personal information (Gender, Name, Date of Birth, ID), the personal information will be automatically registered and move to the measurement screen.
  • Page 13: Measurement

    1) The user’s initial screen is a condition that does not select any gender. This status is in condition of clearing all users’ information. If the user inserts the information and later click on the white area of this box, all information will be deleted. 2) To register the user’s name, select the “Male”...
  • Page 14 Press on the tongs of probe by right hand. (The sensor wire should be placed upper side) Insert left index finger deeply into the PPG probe. Release the tongs of probe. ③ Put hands on the table comfortably and relax and then press NEXT button. ④...
  • Page 15: Report Screen

    ⑤ Do not move or speak while measuring. ⑥ Press STOP button or remove PPG probe from your index finger if you want to stop measurement. It automatically moves to previous screen seconds later after removal of PPG probe. ⑦ The report screen will be shown after the measurement is finished.
  • Page 16  You can print HRV Report, APG Report and/or History Chart by pressing PRINT button on the screen. <<APG History>> <<HRV History>>  When you select the manual mode for the comment, you can insert the comment on the APG Report and click “NEXT”...
  • Page 17: Max Pulse Troubleshooting

    Do not measure while operating the printer: As our equipment collects the data at real time, if you use the printer at the same time, it could cause the trouble in the system. Do not operate other equipment while you are using Max Pulse.: It may not collect the data at the real time.
  • Page 18: Product Warranty

    The warranty shall not be applied to defects resulting from damaged or torn out the WARNING sticker ( ) from main set. ☞ Medicore Co., Ltd. shall not be liable for direct, indirect, or incidental or consequential related to the use of the equipment.

Table of Contents