TCS ISW3030 Product Information

TCS ISW3030 Product Information

Indoor station for hands-free talking
Hide thumbs Also See for ISW3030:

Advertisement

Quick Links

TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88
Mail: hotline@tcsag.de
Indoor station for hands-free talking
Product information
Subject to technical changes.
ISW3030-0140 UK
ISW3030
2 A

Advertisement

Table of Contents
loading

Summary of Contents for TCS ISW3030

  • Page 1 Product information Indoor station for hands-free talking ISW3030 TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 2: Table Of Contents

    Exchange of an indoor station – programming bell buttons ..........14 Cleaning ..........................15 Conformity ........................16 Information on disposal ....................16 Warranty ........................... 16 Service ..........................16 TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 3: Scope Of Delivery

    32 V DC is not exceeded at the connections a, b, P, E. Intended use  ISW3030 are indoor stations for hands-free talking for the object area.  They can be used for the operation within TCS audio systems and combined audio / video systems.  They are suitable for surface-mount.
  • Page 4: Max. Number Isw3030 In 3-Wire Operation

     when no voice communication is established  ring tone if light switch function is activated in the front.door station TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 5: Device Overview

    2-wire operation: I(a) = 1 mA 3-wire operation: I(a) = 0.2 mA, I(P) = 0.8 mA max. input current: I(Pmax) = 75 mA TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 6: Short Description

    TIPP: Avoid tearing of the straps: For fixing the straps do not use counter-head screws or flat washers! TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 7: Connect The Lines (2-Wire Technique)

     The upper cover can be removed at the underside (1).  Lift the upper cover out of the two upper adjustment increments (2). TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 8: Installation Of Extended Functions

    Further wires have to be connected via auxiliar terminals! Use only connecting lines with the same diameter in one terminal contact. TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 9: Wiring Diagram

    07/2015 Wiring diagram Connection diagram 2-wire technique Connection diagram 3-wire technique TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 10: Commissioning

    2-wire operation (delivered state)  Put the jumper J1 at both contacts for the 3-wire operation. 3-wire operation TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 11: Ring Tone Selection

     A signal tone is reflecting the adjusted volume when turning the volume control of the ring tone.  If the setting is finished, the adjusted ring tone will be reflected in the adjusted volume. TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 12: Configuration Options

    (b-wire) in the power supply  Optional strand or star formed wiring TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 13: Principle Loop Resistance

    160 m distance AS/IS-VS by 0.6 mm diameter max. 300 m distance AS/IS-VS by 0.8 mm diameter indoor station extended function TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...
  • Page 14: Repair

    EEPROM of the front-door station.  Ensure that the new indoor station is connected to the TCS:BUS and the mains voltage is switched on (the operation LED at the power supply and control unit is ON) and fur- ther, that the access to the flat is granted during the programming.
  • Page 15: Cleaning

    Do not use any abrasive detergents! Clean the device with a dry or slightly wet cloth. Remove stronger stains with a standard plastic cleaner. TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de...
  • Page 16: Conformity

    TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin | Germany Tel.: +49 (0) 3933/879910, FAX: +49 (0) 3933/879911, www.tcsag.de TCS TürControlSysteme AG, TCS Hotline Germany: +49 (0) 41 94/ 9 88 11 88 Subject to technical changes. Mail: hotline@tcsag.de ISW3030-0140 UK...