FACTORY SETTINGS

Supply Channel
Exhaust Channel

ELECTRICAL CONNECTIONS

WARNING: THIS APPLICATION MUST BE EARTHED. ALL WIRING MUST CONFORM TO LEGAL REQUIREMENTS
AND STANDARDS IN THE COUNTRY WHERE THE APPLIANCE IS USED
The unit is suitable for a 230V, 50Hz single phase supply fused at 3A.
The unit needs a mains flexible cord. Connect the cord to the terminal block and exit through a grommet and cable clamp.
A fused spur, or triple pole switch having a minimum contact separation of 3.0mm, must be used to provide isolation for
the unit. The unit is designed to be wired directly to the mains supply through a fused spur isolator which allows it to run
continuously.