Mitsubishi Electric Mr.SLIM PMH-P25BA Installation Manual
Mitsubishi Electric Mr.SLIM PMH-P25BA Installation Manual

Mitsubishi Electric Mr.SLIM PMH-P25BA Installation Manual

Hide thumbs Also See for Mr.SLIM PMH-P25BA:

Advertisement

Quick Links

Air-Conditioners
·
PMH-P
BA

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
extérieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente
manuale ed il manuale d'installazione dell'unità esterna.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ, ηıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ
ÂÁηٿÛÙ·Û˘ Ù˘ Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÈÓ ·fi ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
exterior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af udendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och utomhusenhetens installationshandbok noga innan luftkonditioneringen installeras så
att den används på ett säkert och korrekt sätt.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dıfl ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR ‹Ç‹N
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr.SLIM PMH-P25BA

  • Page 1: Installation Manual

    Air-Conditioners · PMH-P INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    • The terminal block cover panel of the unit must be firmly attached. rectly installed unit may fall down and cause damage or injuries. • Use only accessories authorized by Mitsubishi Electric and ask a dealer or • The unit must be securely installed on a structure that can sustain its weight.
  • Page 3: Installing The Indoor Unit

    2. Installing the indoor unit The indoor unit should be supplied with the following spare parts and accessories (contained in the inside of the intake grille). (Fig. 2-1) Accessory name Q’ty Washer 4 pcs Washer (with insulation) 4 pcs Pipe cover 2 pcs Band 4 pcs...
  • Page 4 2. Installing the indoor unit (mm) 1 Wooden structures (Fig. 2-5) • Use tie beams (single storied houses) or second floor beams (two story houses) as reinforcing members. • Wooden beams for suspending air conditioners must be sturdy and their sides must be at least 6 cm long if the beams are separated by not more than 90 cm and their sides must be at least 9 cm long if the beams are separated by as much as 180 cm.
  • Page 5: Installing The Refrigerant Piping

    2. Installing the indoor unit (mm) 2.5. Fresh air intake hole (Fig. 2-9) 90° At the time of installation, use the hole (knock out) located at the positions shown in following diagram, as and when required. 288.5 Note: Make sure that the fresh air intake is no more than 20% of the entire air intake (when the air flow speed is set to its highest setting).
  • Page 6: Drainage Piping Work

    3. Installing the refrigerant piping 3.3. Refrigerant piping 1) Indoor unit Installing procedures (Fig. 3-2) 1. Remove the flare nuts and caps from the indoor unit. 2. Flare-cut the liquid and gas pipes then apply refrigerating machine oil (to be lo- cally procured) over the flare-cut seat surface.
  • Page 7: Electrical Work

    5. Electrical work 5.1. Electric wiring (Fig. 5-1) * Make sure all electrical wiring is complete before installing the cover panel. 1. Remove the cover from the address board (two bolts). 2. Remove the cover from the electrical box (one bolt). 3.
  • Page 8: Function Settings

    5. Electrical work 2) Connecting procedures (Fig. 5-4) 1 Connect the remote controller cord to the terminal block. A To TB5 on the indoor unit B TB6 (No polarity) 3) Two remote controller setting If two remote controllers are connected, set one to “Main” and the other to “Sub”. For setting procedures, refer to “Function selection of remote controller”...
  • Page 9: Test Run

    6. Test run 6.1. Before test run s After completing installation and the wiring and piping of the indoor and s Do not carry out this test on the control wiring (low voltage circuit) termi- outdoor units, check for refrigerant leakage, looseness in the power supply nals.
  • Page 10: Installing The Grille

    6. Test run [Output pattern B] Errors detected by unit other than indoor unit (outdoor unit, etc.) Check code Symptom Remark Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Compressor overcurrent interruption U3, U4 Open/short of outdoor unit thermistors Compressor overcurrent interruption (When compressor locked) Abnormal high discharging temperature/49C worked/insufficient refrigerant U1, Ud Abnormal high pressure (63H worked)/Overheating safeguard operation...
  • Page 11 7. Installing the grille 7.3. Installing the grille • Open the intake grille by pressing on the place marked Push, and remove the air filter. • Remove the screw cover in the middle of the blower. • Open the upper and lower flaps on the indoor unit completely. •...
  • Page 12 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.

Table of Contents