Download Print this page

Byron TX-414 Quick Start Manual page 2

Wire free plug-in door chime kit with converter

Advertisement

Wire Free Plug-In Door Chime Kit with Converter-TX-414
Wiring Installation
The Converter is designed to change your new Brass Wired Bell Push to wirefree.
1. Simply connect your Wired Bell Push with the cable from Converter to the terminals on your
bell push.
2. Your Wired Bell Push with Converter is ready to use. In case a Transformer (A/C 8V) is used
to power the Wired Bell Push and Wired Door Chime.
1. Remove the back of the case by pushing in the tab
on the bottom with a small, flat screwdriver.
2. Disconnect the wire that is connected with the
Wired Door Chime.
3. Feed the wire via the hole on the back of the
Converter, connect the wire to the terminal positions
marked in diagrams below.
4. Snap the front cover of converter back on, then it is
ready to use.
Important: Do not connect the Converter unit with
any Lighted Bell Push.
Converter
unit
TX
Chime
1
unit
B and C
Converter
unit
TX
Chime
3
unit
A and C
WIRED
CHIME
(Transformer
operation)
T
Please note that these diagrams are only for reference as a guide.
EACH Wired chime can be wired differently, so if you encounter problems,
PLEASE CALL THE HELPLINE NO. 0121 5449499
Converter unit
Wired Bell
Push
B+C SWITCH
Converter
unit
TX
Chime
2
unit
A and C
WIRED
CHIME
(Battery
operation)
Converter
unit
TX
Chime
4
unit
A and C
WIRED
T
CHIME
(Transformer
operation)
Important
1. Do not mount the Converter unit onto any metal or UPVC doorframes, as this will reduce
the operating range.
2. Do not immerse either unit in water.
3. Do not mount either unit close to fireplace or expose to high temperature.
4. Do not use different type of batteries, or mix up old and new batteries.
5. Do not leave exhausted batteries in either unit. If leaving the doorbell for long period,
remove the battery from compartments to prevent leakage.
6. Always use alkaline batteries as these will give longer service and less likely to leak.
7. The Converter and Door Chime unit are designed for indoor use only.
8. Please dispose of old, defective batteries in an environmentally friendly manner in
accordance with the relevant legislation.
9. Make sure that no naked flame sources, such as lighted candles, should be placed on the
unit.
10. The unit should not be exposed to dripping or splashing and that no objects filled with
liquids, such as vases, shall be placed on the unit.
11. CAUTION: Replace only with the same or equivalent type of battery that are
recommended by the manufacturer.
12. CAUTION: Danger of explosion if battery is incorrectly installed or replaced.
T r o u b l e S h o o t i n g & U s e r H i n t s
Problem
Possible Causes
Chime does not
1. Units are out of range
sound but LED
(max. range 100m)
lights on
2. Converter and Chime units are
Converter
not on the same digital code
3. Converter not wired correctly
Chime does not
1. Flat Converter battery
sound plus no
2. Wrong polarity of battery in
lights on Push
Converter
Converter LED
Chime sounds
A similar Wire Free Door Chime
without Converter
product is operating nearby on the
being pressed
same frequency digital code
NOTE: There are no serviceable parts in the unit, do not attempt to repair it.
Specification
A. Converter unit
Power
: 1 x 12 volt battery (included, replace with Byron model SD-100)
Consumption
: 3.0mA - ON
0.003mA - OFF
B. Door Chime unit
Power
: A/C mains power (230 volt ~ 50Hz)
Operating Temperature
: -10°C to +40°C
Operating Distance
: 100 metres (320 feet approx.) in open field
Selectable Tone
: "Westminster" & "Ding-Dong"
Selectable Digital Code
: Total sixty-four (64) possible digital codes
Suggested Remedy
1. Operate the Chime unit within
the operation range (100m)
2. Re-set the digital code
(see Digital Code Set Up)
3. See wiring diagrams opposite
1. Change the battery
2. Re-insert battery as internal
marking in right polarity
Re-set the digital code
(see Digital Code Set Up)

Advertisement

loading