ACCESSORIES INSTALLATION
60

3rd Party Controller

The product can also be linked to 3rd party controller. You can connect external controllers using
Modbus protocol except for LG controller. If 3rd party controller is used, LG controller is not
applied to AWHP simultaneously.
How to install 3rd party controller
Follow below procedures step 1 ~ step 4.
Step 1. Check if the power of the unit is turned off.
Step 2. Disassemble front panels and distinguish control box(Indoor) of
the unit.
Step 3. Check if the harness(White) is inserted fully to the indoor unit
PCB (CN_COM).
Step 4. Connect the 3rd party controller to terminal block 2(11/12)
completely. (including Meter interface module)
Indoor PCB
Indoor PCB
CN_COM
CN_COM
3(A)
4(B)
rd
3
PARTY
CONTROLLER
(DC 5 V)
3(A)
4(B)
rd
3
PARTY
CONTROOLER