DRAWBACKS AND REMEDIES
The fault of working that are normally found in refrigerating appliances are mostly due to unimportant reasons
or to a faulty electrical installation.
These cases can be easily eliminated on field.
The refrigerator isn't working:
- check that voltage reaches the socket;
- check that the unit is well plugged in;
The inside temperature isn't low enough:
- check that the unit isn't near a source of heat or a draught;
- check if there is too much frost on the walls of the tank;
- check if the thermostat is not set on a wrong position of the thermostat;
- check if the condenser is clogged or obstructed;
- check the perfect closing of the lids;
The unit is noisy:
- check that all screws and bolts are well tightened;
- check if the unit is well levelled;
- check that any tube or fan blade is in contact with other parts of the unit.
TEMPERATURE SETTING AND CONTROLS
Each refrigerating appliance is provided with a thermostat for automatic maintenance of the appropriate pre-
established temperature inside the tank. This temperature adjuster is gauged by the factory and should not
be touched by the user. Only if the average internal temperature is too cold or not cold enough should the
knob (3) turned. The numbers on the regulation plate are not related to temperature values but only to knob
reference position: a higher number corresponds to a lower temperature.
CONTROLS
1) Tank thermometer (no GAMMA 150)
2) Tank thermometer (motor space side)
3) Thermostat
4) Main switch
5) Light switch (GAMMA S)
INFORMATIONS ABOUT SERVICE
0
10
10
2
0
2
0
30
3
0
40
40
1
- 8 -
7
0
10
10
2
0
2
0
0
30
3
0
40
40
1
3
2
G B
4
5
6
5
4
3
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents