6.6.10.
display will show 'std' if this is the required Application then exit 'application mode' by touching
'n2P' touch (+) And use to (-) change back to 'std'.
6.6.11.
Confirm the application 'std', 'tir' or 'n2P' by touching.
6.6.12.
display shows 'aPP' exit the application by touching
6.6.13.
The QUBE will reboot into the desired application and will remain in this mode until an alternative application is required.
6.7.
tyre shoP (tir) oPeration: inflation anD Deflation
6.7.1.
Set desired pressure, by touching either
6.7.2.
Connect the hose to the tyre.
6.7.3.
Automatic inflation will commence to the set pressure, periodically stopping to display the pressure of the tyre.
6.7.4.
If the pressure in the tyre is below 3 psi, 0.3 bar or 30 kpa, the process will not commence until
6.7.5.
When the Set pressure is reached, the buzzer will sound and the display will show 'enD' with the final pressure. Red LED light will
flash.
6.7.6.
Remove the hose from tyre.
6.8.
to enable setting of oPs
6.8.1.
Touch
and display will toggle 'oPs' and blank value.
6.8.2.
Increment the OPS value between 0-29 psi, 0-2 bar, by touching
6.8.3.
Display will revert to the Set pressure previously selected.
note:
The OPS value will not be applied when the tyre has a pressure of more than 3 psi, 0.2 bar.
To prevent the accidental use of OPS, the OPS setting is not retained after the machine is powered down.
Use of oPS:
The OPS value is added to the final target pressure setting to give the Over Pressure.
example:
A Final Set pressure of 32 psi, 2.2 bar is required with an OPS value of 15 psi, 1 bar. The tyre will now inflate from flat condition
only to the value of 47 psi, 3.2 bar.
Once the OPS value has been achieved, the unit will deflate back to the desired set pressure.
For adjustments to Inflators parameters please refer to your Distributor or Sealey.
warning! When using the OPS function, the sum pressure must not exceed the tyre manufactures maximum inflation pressure.
6.9.
n2 (n2P) oPeration; inflation anD Deflation (tyre toP off)
6.9.1.
Set desired pressure, by touching either
6.9.2.
Connect the hose to the tyre.
6.9.3.
The process will not commence until
6.9.4.
When the Set pressure is reached, the buzzer will sound and the display will show 'enD' with the final pressure. Red LED will flash.
6.9.5.
Remove the hose from tyre.
6.10.
tyre Purging (n2 conversion)
6.10.1.
Set desired pressure, by touching either
6.10.2.
Connect the hose to the tyre.
6.10.3.
The process will not commence until
6.10.4.
If the pressure in the tyre is below 3 psi, 0.3 bar or 30 kpa, the process will start but perform only one purge (since the tyre is
already flat).
6.10.5.
during the purging process the display will show the last pressure check point and the number of purging cycles completed when
deflating.
6.10.6.
When the set pressure is reached, the buzzer will sound and the display will show 'enD' with the final pressure. Red LED will flash.
6.10.7.
Remove the hose from tyre.
note:
• In N2 (n2P) Operation the QUBE will not commence inflation until
• For N2 conversion of existing tyres the number of purge cycles is defaulted to 2.
• For flat tyre purging the number of cycles is reduced by 1, as the tyre is already empty.
• The lower purge pressure limit is defaulted to the greater of 10% of the set pressure or 3 psi, 0.2 bar, 20 kpa.
For adjustments to Inflators parameters please refer to your Distributor or Sealey.
6.11.
n2 conversion of existing tyres
For normal use a Purity level of between 93% and 96% N2 is sufficient for most road tyres.
If your N2 Generation source is greater than 97% then it is sufficient to leave the default setting of 2 Purges.
For N2 Generation sources less than 97%, then to achieve the required N2 % Purity, consider adding additional Purge cycles.
For adjustments to Inflators parameters please refer to your Distributor or Sealey.
The Final N2% concentration can be periodically checked using a N2% concentration meter.
6.12.
user insPection MoDe
It is possible to set the inflator to act as a pressure gauge.
The display resolution is changed and can be used to reference the inflator against a calibrated pressure source. The inflator
automatic cycle is inhibited.
6.13.
to access:-
6.13.1.
Touch
and
6.13.2.
The QUBE will beep but the display will not change.
6.13.3.
Touch
5 times (if this is not undertaken within 10 seconds, the Inflator reverts back to normal Inflator mode).
6.13.4.
display will show the pressures to the minimum resolution: psi = 0.1 / Bar = 0.01 / kpa = 1 / kg/cm = 0.01.
6.13.5.
Connect the hose to the tyre and the display will show the pressure in the tyre.
6.13.6.
When complete, touch any button to return to the last set mode.