Quick Links

No. F-120R-E
Thank you for purchasing our Stat Clean No. F120R-E.
Read this instruction manual before use. Keep it in a safe handy place for future reference.
Read this instruction manual before use. Keep it in a safe handy place for future reference.

Table of Contents

■For Your Safety ································································
■Product Features ································································
■Production Specifications ································································
■External View ································································
■Performance ································································
■Installation ·····················································································
■Before Use ····················································································
■Operation ······················································································
■Maintenance ································································
■Troubleshooting ································································
■Storage ·························································································
■Warranty ·······················································································
·············································· P.14
············································ P.15
·································· P.15
················································· P.16
·················································· P.17
·················································· P.21
·············································· P.23
13
Instruction Manual
Instruction Manual
····················· P.17
···················· P.18
······················ P.19
························· P.23
······················· P.24

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Stat Clean F-120R-E and is the answer not in the manual?

Questions and answers

Summary of Contents for Vessel Stat Clean F-120R-E

  • Page 1: Table Of Contents

    Instruction Manual Instruction Manual No. F-120R-E Thank you for purchasing our Stat Clean No. F120R-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents ■For Your Safety ································································...
  • Page 2: For Your Safety

    ●Safety precautions in this instruction manual are categorized into two types by the degree of danger associated with each of the followings. Based on danger analyses performed by Vessel, all precautions in this instruction manual are of the CAUTION level.
  • Page 3: Product Specifications

    Product Features ■Variable louver function • The airflow direction angle on the front cover can be changed to straight or wide to set the static erasing range. ■Safe design • When the front cover is removed, the circuit is shut off and the power is turned OFF to prevent electric shocks.
  • Page 4: External View

    : DC output cable: approx. 1.8 m, AC input cable: approx. 1.8 m Weight : 135 g Consumables Electrode Needle Unit : F-120RCH *The measurement values were obtained using the VESSEL measurement environment, so errors could be induced depending on the operation environment. External View № F120R-E...
  • Page 5: Performance

    External View No.AD-24-IT-EX Performance Static elimination efficiency Based on IEC61340-4-7 compliant CPM : TREK 158, Temperature:25℃, Humidity:50% , Humidity:50% ■Straight airflow at HI fan speed ■Wide-angle airflow at HI fan speed angle airflow at HI fan speed The above values were based on tests with a sample unit. They represent the central tendency of this model, but they are not guaranteed.
  • Page 6: Before Use

    Installation ⚠CAUTIONS (cont.) Do not use the F120R-E based on environments stated below. PROHIBITED Adverse environments can result in explosion, fire, electric shock and accident. *Where explosion-proofing is required; *Where flammable atmospheres are found; *Where a significant vibration and/or impact is given; *Where temperature and humidity exceed specified ranges;...
  • Page 7: Operation

    Before Use Connector connection (cont.) Pin assign From wiring side: 4 – GND, 1 - +24V Power Supply Adapter Use the power adapter (AD24-IT) which is specifically designed for use of the F120R-E. The AC adapter plug is a 3-pronged plug. Connect this to a power outlet that has a ground terminal.
  • Page 8 Operation ALARM LAMPS H.V. Alarm (High voltage alarm lamp) The lamp lights in green when the high voltage transformer emits properly the high voltage. If the piezoelectric transformer detects an overload and shuts down the operation, the high-voltage alarm lamp will light up in red. When the H.V.
  • Page 9: Maintenance

    Maintenance Filter (Option) (cont.) ⚠CAUTIONS Do not disassemble the F120R-E. Servicing is reserved for service DO NOT DISASSEMBLE engineers. Electric shock, malfunction, or injury may occur. Before making checks, unplug the power cable. Working with the ● UNPLUG POWER CABLE power on can result in electric shock and breakdown.
  • Page 10 Maintenance Electrode Needle Cleaning/Replacement (cont.) ⚠CAUTION If the discharge needle is dirty, it could lower the static erasing performance or cause dust to fly around. Be sure to clean the contaminated parts according to your service ● CLEANING condition. When replacing the Electrode Needles If the static erasing performance does not recover even after cleaning the electrode needles, they may be worn out.
  • Page 11: Troubleshooting

    Troubleshooting Using the F120R-E in anything but proper working condition can cause damages on the product or accidents/injuries on the personnel. Therefore, promptly request servicing if trouble occurs. For servicing, contact us or our distributors. ⚠CAUTIONS Do not use the F120R-E in the following situations. It may result in fire or electric shock.
  • Page 12: Warranty

    Defective products must be returned to VESSEL Osaka Japan with proof of purchase date. And if your unit is out of warranty, VESSEL will quote repair charges necessary to ship your unit freight prepaid to where you have originally purchased.