Page 1
Instruction Manual Quality does it Thank you for purchasing our Stat Clean No. F12E-E. Read this instruction manual before use. Keep it in a safe handy place for future reference. Table of Contents ■For Your Safety·······························P.2 ■Product Features ····························P.3 ■Production Specifications ···············P.4 ■External View··································P.5 ■Performance ···································P.6 ■Installation·······································P.7...
●Safety precautions in this instruction manual are categorized into two types by the degree of danger associated with each of the followings. Based on danger analyses performed by Vessel, all recautions in this instruction manual are of the CAUTION level.
Product Features ■AC-TYPE CORONA DISCHARGE This static eraser works by AC corona discharge, therefore ion balance is not disturbed by accumulating dust on the electrode wire. Use a new 8-electrode design to efficiently generate ions with minimal loss due to rebonding. ■FAN-TYPE STATIC ELECTRICITY ERASER 120 mmSQ high power DC fan is built in to blow drafts long distances.
/humidity :DC input cable:1.8 m , AC output cable:1.8m Cable length :135g Weight Consumables :F-12EH :F-12EF Wire plate Filter *The measurement values were obtained using the VESSEL measurement environment, so error could be induced depending on the operation environment.
Page 6
Performance Static elimination efficiency Based on ANSI EOS/ESD S3.1 com compliant CPM:TREK 158, Temperature:25 ,Humidity:50% Top row:Ion Balance value Middle row:Attenuation time from +1000 V to +100 V Bottom row:Attenuation time from-1000 V to -100 V <At max. fan speed> The values above were based on tests with a sample unit.
Installation CAUTIONS IN INSTALLATION Use only the included power supply adapter. Use of other adapters may REMEMBER results in fire, electric shock and static electricity removal trouble. Install F12E-E securely. F12E-E can be damaged or malfunctioned if it falls. REMEMBER Install F12E-E based on below stated environment.
Before Use CAUTIONS IN BEFORE USE Use only the included power supply adapter. Use of other adapters may REMEMBER results in fire, electric shock and static electricity removal trouble. If noticing anything strange, stop using F12E-E immediately. REMEMBER Do not use F12E-E other than static electricity removal. PROHIBITED Do not remodel or disassemble F12E-E.
Operation POWER This is used to start and stop the unit. When switched to [ ― ], the power is turned on, the switch LED lights up, and operation starts. When switched to [ ○ ], the power is turned off and operation stops.
Maintenance CAUTIONS IN MAINTENANCE AND CHECKS DO NOT Do not disassemble F12E-E. Servicing is reserved for service engineers. DISASSEMBLE Before making checks, unplug the power cable. Working with the power UNPLUG on can result in electric shock and breakdown. POWER CABLE Do not wipe F12E-E with detergent or solvent.
Page 11
Maintenance Electrode Wire Needle Cleaning/Replacement After using long hours, dust adhered around the electrode wires. Dust adhesion can lower the performance of ionizing. Periodically clean or replace the electrode wires. 1) Before cleaning the electrode wires, shut OFF power and unplug the power supply adapter from the electrical outlet.
Page 12
Maintenance When cleaning the filter After being used for a long time, dust adhered to the filter could lower ionizing performance or cause dust to fly around. Periodically clean or replace the filter. 1) Before cleaning the filter, shut OFF power and unplug the power supply adapter from the electrical outlet. 2) Remove and clean the filter.
Troubleshooting Using F12E-E when in anything but proper working condition can cause product damage or personal accident. Therefore, promptly request servicing if trouble occurs. For servicing, contact the place of purchase. CAUTION TROUBLESHOOTING Do not use F12E-E in the following situations. It may result in fire or electric shock.
Page 14
Storage In the following cases, contact the supplier for servicing. Do not service F12E-E yourself as this can be dangerous. * If the power lamp does not light when the power switch is in the ON position * If air is not blown when the fan speed varistor is turned * If the casing moves during use and air blow turns on and off * If the power cable is excessively hot * If the power supply adapter is excessively hot...
Page 16
Defective products must be returned to VESSEL Osaka Japan with proof of purchase date. And if your unit is out of warranty, VESSEL will quote repair charges necessary to ship your unit freight prepaid to where you have originally purchased.
Need help?
Do you have a question about the STAT-CLEAN F12E-E and is the answer not in the manual?
Questions and answers