G Sensor Calibration - Ricoh Sargas-PJ1 Field Service Manual

Machine codes: y095/y096/y097/y098
Table of Contents

Advertisement

6.
Check the calibration result (red frame).
7.
Compare the results with the default values.
Default Values: R:720, G:1022, B:708
If the result are the same as the default values, the calibration has failed.
When the calibration failed, check the video source and redo the ADC calibration.

G Sensor Calibration

After replacing the main board, this calibration must be done.
1.
Put the projector on a horizontal surface.
2.
Get into service mode.
3.
Select "G Sensor Calibration", and then press the "Enter" key.
(page 78 "How to enter the Service
Mode")
Calibration
97