Download Print this page

Galvin Specialised Ezy-Wash TF78WC-ESS Product Installation Manualline

Food service tapware

Advertisement

Quick Links

®
Ezy-Wash
Food Service Tapware
PRODUCT CODES:
- TF78WC-ESS
SPECIFICATIONS
The Galvin Specialised Ezy-Wash
The wall mounted hot and cold lever mixer features a polished chrome plated body for optimum stability.
This Ezy-Wash
®
product is laminar flow (not aerated).
Our highly sought after lever handle design is easily operated with elbows, wrists or hands.
Quick action SBA's include a brass jumper valve component, with red and blue indicator buttons on 150mm
lever action handles.
This unit is supplied with a wall mounted stainless steel cable to provide strength to the spout when using
the hook for bucket filling.
IMPORTANT: All Ezy-Wash
good working order.
TECHNICAL DATA
Inlet
Outlet
Headwork
Working Pressure Range (kPa)
Working Temperature Range (°C)
Nominal Flow Rate (LPM)
Finish
NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice.
TOOLS REQUIRED
Power drill, Spanner & Hex Key
Thread tape or Sealant.
®
product range is used for hand sinks, bar sinks and more.
®
product taps are tested in accordance with AS/NZS 3718 and leave our premises in
½" BSP – Female
Laminar Flow
Jumper Valve
Min
50
Max
500
Min
5
Max
80
7.5
Chrome

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ezy-Wash TF78WC-ESS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Galvin Specialised Ezy-Wash TF78WC-ESS

  • Page 1 Working Pressure Range (kPa) Working Temperature Range (°C) Nominal Flow Rate (LPM) Finish Chrome NOTE: Galvin Specialised continually strive to improve their products. Specifications may change without notice. TOOLS REQUIRED  Power drill, Spanner & Hex Key  Thread tape or Sealant.
  • Page 2 1300 514 074 INSTALLATION IMPORTANT: Galvin Specialised products must be installed in accordance with these installation instructions and in accordance with AS/NZS 3500, the PCA and your local regulatory requirements. Water and/or electrical supply conditions must also comply to the applicable national and/or state standards. Failing to comply with these provisions shall void the product warranty and may affect the performance of the product.
  • Page 3 3. Fit grub screws 4. Fit bracket  Ensure the body is pushed firmly against the tail and  With the supplied screws, secure the top and then secure in place with the supplied grub screws. lower halves of the bracket to the spout ...
  • Page 4 TROUBLESHOOTING PROBLEM CAUSE RECTIFICATION Jumper valves are worn or damaged Replace jumper valve Taps are dripping water Tap seat is damaged Refurbish tap seat using a reseating tool. Water is leaking O-ring on jumper valve spindle Replace o-ring from spindle is damaged or worn Water is turned off Turn water on...