Download Print this page

jablotron JA-181M Quick Start Manual page 2

Wireless magnetic door detector & universal transmitter

Advertisement

The JA-181M wireless magnetic door detector & universal transmitter
not be delayed by more than two weeks. This should be done by a
qualified technician with the control panel in Service mode.
Expired batteries should not be thrown into the garbage, but
disposed of according to local regulations.
Removing the detector from the system
If a detector is removed, the control panel announces the
removal. The detector has to be deleted in the control panel before
intentional removal.
Technical parameters
Voltage
Lithium battery type LS(T)14500 AA (3.6V / 2.4 Ah)
Typical battery lifetime
Communication band
Communication range
Typical sensitivity range of the built-in magnetic sensor
Inputs for external sensors
IN1 normally closed or balanced loop (1k resistor)
The maximum length of the cable for external detectors
Dimensions, weight
Operational environment according to EN 50131-1 II. Indoor general
Operational temperature range
EN 50131-1, EN 50131-2-6, EN 50131-5-3 classification:
Complies with
Can be operated according to
JABLOTRON
ALARMS
JA-181M is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. The
original of the conformity assessment can be found at
www.jablotron.com, Technical Support section
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the producer after use.
The JA-181M wireless magnetic door detector & universal transmitter
approx. 3 years
for 20 daily activations maximum
868.1 MHz, Jablotron protocol
approx. 300m (open area)
- see the picture
IN2 and TMP = normally closed loops
3 meters
110 x 31 x 26 mm, 90g
magnet: 56 x 16 x 15 mm
-10 to +40 °C
ETSI EN 300220, EN50130-4,
EN55022, EN 60950-1
ERC REC 70-03