Download Print this page

BVF 23-FA User Manual

Rf thermostat with plug receiver

Advertisement

Quick Links

User manual

BVF
23-FA
RF Thermostat with plug receiver
The unit consists of two parts: 23-F controller and 23-A receiver. The controller has been developed to operate electric heating panels or conven-
tional electric heating units. Receiver part is designed for standard electric outlet. The controller can be accommodated anywhere in the room.
1.
DISPLAY AND BUTTONS
10
9
8
1
+ button
Increase temperature (change value at settings)
2
– button
Decrease temperature (change value at settings)
3
Back
Back to main page
4
Menu
Set time / Select Mode
5
PRG
Programming
6
On/Off
Turn unit On /Off
7
Actual mode
Displays actual mode
8
Temperature
Displays actual temperature
9
Clock
Displays actual time
10 Weekday
Displays actual weekday
11 Cycle time
Displays actual cycle time
www.bvfheating.com
BVF_23-F_ENG_v1.0_20170622.indd 1
11
7
6
5
4
TECHNICAL
DATA
Thermostat Operating Voltage: 2 x AAA 1.5V, alkaline batteries
Receiver Current Load:
Backup Storage:
Maximum load:
Frequency:
Switching options:
Temperature settings:
Accuracy:
Thermostat dimensions:
Receiver dimensions:
Color:
IP protection rating:
Certifi cation:
PRODUCT
FEATURES
Large display can be clearly read with the background
lighting
Easy to fi t without installation works
Six buttons make it easy to use
4 periods of each day programmable (5+1+1)
The display shows the set and the measured temperature
The thermostat is supplied with a wall-fi xing fram and
desktop stand
13
1
15
2
3
12 Power on LED indicator
13 Heating on LED indicator
14 Setup in progress LED indicator
15 Pairing device button
230V, 50/60Hz
EEPROM
230V / 16A
868MHz / 433MHz
5+1+1 day, 4 periods each day
5°C ~ 30°C, 0.5°C increments
+/- 0.5°C
135mm x 88mm x 22mm
114mm x 86mm x 30mm
White
20
CE
12
14
2017. 06. 26. 12:08:01

Advertisement

loading

Summary of Contents for BVF 23-FA

  • Page 1: User Manual

    User manual 23-FA RF Thermostat with plug receiver TECHNICAL DATA Thermostat Operating Voltage: 2 x AAA 1.5V, alkaline batteries Receiver Current Load: 230V, 50/60Hz Backup Storage: EEPROM Maximum load: 230V / 16A Frequency: 868MHz / 433MHz Switching options: 5+1+1 day, 4 periods each day Temperature settings: 5°C ~ 30°C, 0.5°C increments...
  • Page 2 User manual TEMPERATURE CALIBRATION You might need to calibrate the temperature sensor for the fi rst use. Turn off the controller, press and hold the MENU button for 3 seconds. Use the + and – buttons to set the temperature value. This value can be adjusted within -8 to +8°C in 0,5°C increments. SETUP TIME AND SELECT MODE Set up actual time and weekday After turning the controller on, press MENU button and hold 3 seconds, the time display will start fl...