Download Print this page

Mandik MMC Installation And Operating Instructions Manual page 8

Advertisement

Available languages

Available languages

1)
To enter the weekly program, press and hold the button
2)
Instead of time the inscription LOOP appears on the screen, use the
a) If we set the number 5, we will heat 5 days a week according to the set program and the temperature
for weekend will be set separately. The format of the week is 5 + 2
b) If we set the number 6, we will heat 6 days a week according to the set program and set the
temperatures for Sunday will be set separately. The format of the week is 6 + 1
c) If we set the number 7, all the days of the week will be heated the same way. The format of the week
is 7.
3)
Day of the week can be divided into 6 events (6 sections with different temperatures), if you set the
format of the week to 6 + 1 or 7, the weekend is divided into 2 events. After selecting the week format,
use the button
the temperature and time settings.
4)
The settings is made according to the following table 4.1. Temperature and time values are preset.
1
2
Day of the
3
week
4
5
6
1
Weekend
2
This setting can be entered when the device is switched off by holding down the button
setting is done according to the following table 5.1. Use the
setting by pressing
.
1
ADJ
Temperature calibration
2
CTL
Fan control option
3
OLT
Output voltage limit
4
AdH
Communication address high
5
AdL
Communication address low
6
LTP
Low temperature protection
7
SEN
Sensor mode
8
FAC
Reset to factory seting
to switch between the individual time periods and the button
V
06:00
08:00
11:30
12:30
Time
setting
17:30
22:00
08:00
22:00
button to jump between settings. Leave the
0
Adjust temperature range: -5 to +5°C
0
Uncontrol: 0
10
Adjust range: 5-10V
0
0x00-0xff
1
0x00-0xff
0
0: off
0: built-in sensor
0
1: external sensor
8
Reset by setting the value to 0
8
V
to select the week format
to switch between
V
20°C
15°C
15°C
15°C
Temperature
setting
22°C
15°C
22°C
15°C
and
V
control: 1
1: on
. The

Advertisement