Keysight 81150A and 81160A
Pulse Function Arbitrary
Noise Generators
Demo Guide, Version 1.0

Advertisement

loading

Summary of Contents for Keysight Technologies 81160A

  • Page 1 Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators Demo Guide, Version 1.0...
  • Page 2 High precision pulse generators enhanced with versatile signal generation, modulation and distortion capabilities for: – Accurate signals to test your device and not your signal source – Versatile waveform and noise generation to be ready for today‘s and tomor- row‘s stress test challenges –...
  • Page 3 03 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide The 81150A Pulse – 1 µHz – 120 MHz pulse generation with variable rise/fall time – 1 µHz – 240 MHz sine waveform output Function Arbitrary –...
  • Page 4 04 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide The 81160A Pulse – 1 µHz – 330 MHz pulse generation with variable rise/fall time – 1 µHz – 500 MHz sine waveform output Function Arbitrary –...
  • Page 5 05 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 811 A Waveform type Advanced mode Trigger mode Couple/uncouple channels USB 2.0A Channel 2: Channel 1: External In Trigger out Trigger out Strobe out Strobe out...
  • Page 6 06 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 811 A Waveform type Advanced mode Trigger mode Couple/uncouple channels USB 2.0A Channel 2: Channel 1: Sync out A and B: Differential Differential The logical trigger signal 1...
  • Page 7 4. Connect ‘TRIGGER OUT 2’ (81150A), ‘Sync Out A’ (81160A) to channel 4 (scope) 5. 81160A only: select ‘Ch 2’, select ‘Trig’, go to ‘Trigger Out’ and set it to ‘Sync A’ 6. 81160A only: set ‘Strobe Out’ to ‘Sync B’...
  • Page 8 08 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide In this lab it is shown how two channels can be coupled, so that the instrument Coupling between behaves like a two-channel instrument with only one timebase. As a result of...
  • Page 9 09 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 3) Enable the trigger mode Select ‘TRIGGER MODE’ for Ch2 (button ‘Trig’) Select ‘SINEWAVE’ as trigger signal Enter trigger source (e.g. External In) Triggered by rising edge TRIGGER OUT’...
  • Page 10 10 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide In this exercise we add the output signals of the two independent output chan- Channel adding nels together. This is the only way to generate distorted signals out of standard (this requires a two waveforms.
  • Page 11 11 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 3) Perform channel addition Select ‘CHANNEL 1’ Press ‘UTILITY KEY’ and choose the ‘OUTPUT SETUP’ softkey Press the ‘CHANNEL ADD’ key once. To reset it to separate channels, press the key again.
  • Page 12 4. Connect ‘TRIGGER OUT 2’ (81150A), ‘Sync Out A’ (81160A) to channel 4 (scope) 5. 81160A only: select ‘Ch 2’, select ‘Trig’, go to ‘Trigger Out’ and set it to ‘Sync A’ 6. 81160A only: set ‘Strobe Out’ to ‘Sync B’...
  • Page 13 13 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 2) Define the customized waveform 1. Enter the number of waveform points (maximum number is 16384) 2. Enable the linear interpolation to have straight-line connection between points.
  • Page 14 14 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide B) Add noise to the In this exercise we generate noise on channel 2 and add it to the output signal of channel one. ARB waveform (this...
  • Page 15 15 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide 3) Remote control of the 81150A The Keysight 81150A and 81160A are LXI Class C compliant and therefore have and 81160A a web browser installed. It is very easy to control the unit via a web server.
  • Page 16 16 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide Continuous Available modes of operation 81150A and 81160A Pulse Square Sine Ramp Noise Advanced mode: off Advanced mode: burst Advanced mode: Modulation Advanced mode: sweep Internally triggered or externally triggered...
  • Page 17 17 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide Keysight 81150A Ordering Information #001 1-channel pulse function arbitrary noise generator for the Keysight 81150A #002 2-channel pulse function arbitrary noise generator #1A7 ISO17025 calibration documents #Z54 Z540.3 calibration documents...
  • Page 18: Ordering Information

    18 | Keysight 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide Keysight 81160A Ordering Information #001 1-channel pulse function arbitrary noise generator #002 2-channel pulse function arbitrary noise generator #1A7 ISO17025 calibration documents #Z54 Z540.3 calibration documents...
  • Page 19: Related Literature

    19 | Keysight | 81150A and 81160A Pulse Function Arbitrary Noise Generators - Demo Guide Related Literature Related Literature 81150A and 81160A Pulse Function 81160A Pulse Function Arbitrary Noise Generator Quick Fact Sheet Arbitrary Noise Generator Data Sheet 5989-6433EN 5990-6984EN...