Wa rning: Watch out for possible (life-threatening) injuries. For any remarks, wishes or omissions you can contact Kabola Heating Systems. W e also welcome any remarks to improve this manual. We wish you a lot of pleasure from your purchase.
Contents Preface Contents Introduction General Introduction. Range application Product description Technical specifications Safety General safety Safety instructions Transport and storage Transport Storage Installing and preparing for first use Installation 4.1.1 Fitting the boiler 4.1.2 Connection of the Central heating system 4.1.3 Flue gas outlet 4.1.4...
Introduction General Introduction. Congratulations with your purchase of this Kabola boiler. This user-manual covers the B-Series central heating boilers. The B-Series central heating boilers cover a wide range of boilers with a broad range of application. By purchasing this boiler you have acquired a product, which is of high quality through the application of the latest European standards and directives.
Ensure that the boiler is only used when the boiler is in sound technical condition. • Ensure that the safety regulations are observed whilst operating the boiler. Atte ntion: No alterations to the boilers may be done without the explicit written consent of Kabola Heating Systems! Safety instructions The safety instructions listed below must be complied with when operating the B-Series boilers.
Transport and storage Transport Take following precautions before transporting the boiler: • Drain the water from the boiler • Uncouple the fuel system • Remove the burner (see 4.1.5, replacing the burner) While transporting the boiler, take following precautions: • Don’t damage the boiler, use a blanket to cover the boiler.
• Use a earthed plug socket for connecting the 230 V AC versions to the power supply. 4.1.2 Connection of the Central heating system Piping Take note of the following points, when installing the piping: • Install the piping in such a way, that the boiler (cover and dashboard) remains accessible. •...
Hint: To reduce the noise resulting from flames, it is wise to install a silencer in the horizontal flue and the vertical flue. Kabola can provide you with all components which may be required for installation such as: • Cowls.
4. Connect point 2 of the connector to point L1 of the room thermostat. Atte ntion: The core diameter of the connections mentioned above must be between 1 and 1,5mm². The wires should be suitable for the voltage used. Conne cting the circulation pump (see figure 5 and electrical scheme in appendix C) Connect the pump to points 3 and 4 of the connector.
Ble eding the circulation pump The circulation pump can only be bled when the electrical circuit is connected, because this has to be done with a running pump. Follow the points listed below to bleed the pump (see figure 8): Check if the rotor can rotate without problems by turning the pump by hand (see manual pump) Loosen the screw on front of the pump ½...
4.1.7 Connecting the oil filter and oil burner To connect the filter to the boiler follow the procedure below (see also figure 11) Figure 11 Remove the burner cover (1); Connect the oil pump (2) to the oil-filter (3), using the included fuel hoses.
When ordering spare parts, mention the type of the boiler and its serial number. Kabola Heating Systems will then be able to deliver the correct parts. In Appendix B, the main spare parts are listed.
Change the oil filter element; Clean the burner (see manual of the burner) Hint: Kabola Heating Systems has a standard set with replacement parts for the yearly maintenance (see Appendix B) Atte ntion: The old oil filter element has to be processed as chemical waste.
Following spare parts are available. 25 Nozzle See Appendix A For the yearly maintenance Kabola Heating Systems has compiled a set of spare parts often used during maintenance. 26 Service set comprising of 4+23+25 Use r ma nual Ka bola B-serie, 1-4-2005...
Appendix F Troubleshooting Listed below you will find a list with possible problems, their reasons and solutions. When you encounter problems not listed, you should contact your dealer. Never try solve proble ms on your own. Problem Possible reason Possible solution Burner won’t start Oil supply interrupted Bleed the oil filter...