  • Page 1 User manual Kabola HRE serie Kabola Heating Systems BV Placotiweg 1E 4131 NL Vianen (Utr.) Nederland...
  • Page 2: Preface

    Phone +31 (0)347-320030 +31 (0)347-355688 Web: www.kabola.nl E-mail info@kabola.nl Vianen, November 2013 © 2013 Kabola Heating Systems Copying of (parts of) this manual, is only allowed with written consent of Kabola Heating Systems. User manual HRE-serie version 6, November 2013...
  • Page 3: Table Of Contents

    Table of contents Preface Table of contents 1 Introduction 1.1 General 1.2 Range of application 1.3 Product description 1.4 Technical specifications 2 Safety 2.1 General safety 2.2 Safety instructions 3 Transport and storage 3.1 Transport 3.2 Storage 4 Installing and preparing for first use 4.1 Installation 4.1.1 Fitting the boiler 4.1.2 Connection to the central heating system...
  • Page 4: Introduction

    1 Introduction 1.1 General Congatulations with your purchase of this Kabola boiler. This user-manual covers the HRE-series. The HRE-boilers cover a wide range of boilers with a broad range of applications. By purchasing this boiler, you have acquired a product, which is of high quality through the application of the latest European standards and directives.
  • Page 5: Safety

    In this chapter we emphasizes the safety-related points for operating the boiler. 2.1 General safety Warning: Although Kabola Heating Systems designs and produces its products according to the current safety standards, it is possible that dangers may present themselves, which could lead to injuries or damage to the boiler, if the safety instructions in this manual are not complied with.
  • Page 6: Transport And Storage

    3 Transport and storage 3.1 Transport Take following precautions before transporting the boiler:  Drain the water from the boiler;  Uncouple the fuel system;  Remove the burner (see § 4.1.5, replacing the burner). While transporting the boiler take following precautions: ...
  • Page 7: Installing And Preparing For First Use

    4 Installing and preparing for first use In this chapter you will find directions and hints for a correct placement and fitting of the boiler and accompanying parts. Warning: Do not store any flammable or gaseous substances in the room where the boiler installed.
  • Page 8: Connection To The Central Heating System

    4.1.2 Connection to the central heating system PIPING Take note of the following points, when installing the piping:  Install the piping in such a way, that the boiler (cover and dashboard) remains accessible;  Provide enough bleeding points in places where air may collect, especially near the boiler. Attention: Install a bleeding point near the boiler, especially when the piping...
  • Page 9 Hint: To reduce the noise from flames, it is wise to install a silencer in the flue. Your Kabola supplier can provide you with all components which may be required for installation such as: Figure 4  Cowls;  Flexible piping;...
  • Page 10: Electrical Connection

    4.1.5 Electrical connection Warning: Disconnect the power supply from the boiler before you start the installation. The quality of 230 VAC power supply to the boiler should be as good as the power supply from a land line. Figure 5 Connecting the room thermostat (Figure 5a &...
  • Page 11: Filling The Central Heating System

    4.1.6 Filling the central heating system The pressure in the system should:  Never be lower than 0,5 bar cold;  Never be higher than 2,5 bar hot. Follow the procedure below for filling the CH-system (see figure 7):  Switch off the boiler; ...
  • Page 12: Mounting The Oil Burner

    4.1.7 Mounting the oil burner Follow the instruction below for mounting the oil burner:  Passionate the insulation (2) and the burner clamp (3) that they are in one line with the mounting holes in the door.  Assemble the burner clamp with the 4 M8 bolts. The arrow at the burner clamp must point to the top.
  • Page 13: Starting Your System

    To be eligible for warranty, the boiler has to be adjusted by an approved installer. Contact your Kabola supplier to make an appointment. Never adjust the burner using your own initiative.
  • Page 14: Explanation Of The Dashboard

    5.1 Explanation of the dashboard < A < C < D < B Figure 13 Explanation from the number in the figure 13: Fuse holder with a glass fuse 10A 230V, On/ off switch, Analogue display for boiler temperature , Adjust nob for boiler temperature, Reset nob maximal thermostaat.
  • Page 15: Cleaning And Maintenance

    Spare parts must be ordered through your Kabola supplier. For warranty purposes only original spare parts must be used. When ordering spare parts, state the type of boiler and its serial number. Your Kabola supplier will then be able to supply the correct parts. In Appendix B, the main spare parts are listed.
  • Page 16: Appendix A Technical Specifications

    Appendix A Technical specifications Boiler dimensions Letter HRE300 HRE400 HRE500 Technical specifications HRE300 HRE400 HRE500 Flue gas Ø C.H. connection Max. capacity 8-10 10-14 Service pressure Working pressure Weight Exhaust gas temp. Max. ºC Efficiency Max. length horizontal max. mtr.
  • Page 17: Appendix B Electrical Diagram 230 V

    Appendix B Electrical diagram 230 V User manual HRE-serie version 6, November 2013...
  • Page 18: Appendix C Troubleshooting

    Appendix C Troubleshooting Listed below you will find a list with possible problems, their reasons and solutions. When you encounter problems not listed, you should contact your dealer. Never try to solve problems on your own. Problem Possible reason Possible solution Burner will not start Oil supply interrupted Bleed the oil filter...
  • Page 19: Appendix D Boiler Parts

    Stainless steel eficiency tube HRE300-400 14-N219 Stainless steel eficiency tube HRE500 14-N225 Insulation door 294 x 294 x 20 mm HRE300 9-I081 Insulation door 300 x 300 x 20 mm HRE400 9-I082 Insulation door 355 x 300 x 20 mm HRE500 9-I096 Door gasket cord HRE-serie 15 mm per m.
  • Page 20: Appendix E Burner Parts

    Appendix E Burner parts. User manual HRE-serie version 6, November 2013...
  • Page 21 Discription Article number Casing burner house Air intake Air intake casing Flame tube Burner fixing flange Isolation burner Air flap Lid burner casing Burner transformator Ignition cable with connector 35-041 Burner automat Siemens LMO24 7 Pole connector 4-D164 Adjust mutter Fixing mutter Pilar burner cap Photo cel...
  • Page 22: Appendix F Eg-Declaration

    Kabola Heating Systems BV Placotiweg 1 E 4131 NL Vianen The Netherlands decIare under our own responsibility that the product: Kabola HRE300/ HRE400/ HRE500 230 V to which this declaration relates complies with the fol/owing standards 303-1, 303-2, 304, 50081-1, 50082-1.
  • Page 23: Appendix G Ce Certification

    Appendix G CE certification User manual HRE-serie version 6, November 2013...