Expert PDU Energy 8310 Series
© 2014 Gude Analog- und Digitalsysteme GmbH
Manual Ver. 1.1.0
valid from Firmware Ver. 1.1.1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Expert PDU Energy 8310 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gude Expert PDU Energy 8310 Series

  • Page 1 Expert PDU Energy 8310 Series © 2014 Gude Analog- und Digitalsysteme GmbH Manual Ver. 1.1.0 valid from Firmware Ver. 1.1.1...
  • Page 2 Have your Gude devices always in view - and in control. With the free Gude Control App you can retrieve all relevant information from your GUDE products regardless of their current whereabouts. Check with your smartphone the important operating figures of your server and rack environment like sensor values (max/min), energy consumption as well as state of inputs and outputs with watchdog functions.
  • Page 3: Table Of Contents

    Expert PDU energy 8310 Table of contents Table of contents Chapter 1 Safety Advice Chapter 2 Description Chapter 3 Hardware Content of delivery Installation Usage and Display Chapter 4 Configuration DHCP Network settings with GBL_Conf Configuration via webinterface 4.3.1 Configuration - IP Address 4.3.2 Configuration - IP ACL 4.3.3...
  • Page 4: Content Of Delivery

    Expert PDU energy 8310 Safety Advice Safety Advice The device must be installed only by qualified personnel according to the following installation and operating instructions. The manufacturer does not accept responsibility in case of improper use of the device and particularly any use of equip- ment that may cause personal injury or material damage.
  • Page 5: Usage And Display

    Expert PDU energy 8310 Hardware Usage and Display Status LED The status LED shows directly the state of the device: Red: The device is not connected to the Ethernet. Orange: The device is connected to the Ethernet, TCP/IP settings are not defined. Green: Your device is connected to the Ethernet, TCP/IP settings are assigned.
  • Page 6: Chapter 4 Configuration

    Freq 50.02Hz Powerfact -0.3 The power frequency (50Hz in the German electricity grid) and the power factor. Gude PDU 8310 192.168.1.123 This page provides information on the product name and the assigned IP address. Firmware 1.0.0 MAC:001932003f09 The firmware version number and used the MAC ethernet address.
  • Page 7: Configuration Via Webinterface

    Expert PDU energy 8310 Configuration Configuration via webinterface Enter the IP address of the device into the address line of your internet browser: http://”IP address of unit”/ and press LOGIN. To enter the configuration menu, click on „Configuration“ Tab. Configuration - IP Address 4.3.1 4.3.1.1 Hostname...
  • Page 8: Configuration - Ip Acl

    „http://192.168.0.1“ or „http://192.168.0.1/24“ If you locked yourself out by mistake, please activate the bootloader mode, start Gbl_Conf.exe and deactivate IP ACL. You can find more information about configuration of IP ACL or have a look at http://www.gude.info/wiki. 4.3.2.1 Reply ICMP-Ping requests...
  • Page 9: Configuration - Http

    Expert PDU energy 8310 Configuration 4.3.2.2 Enable IP Filter Here you can activate the IP Access Control List (IP ACL). If IP ACL is active, DHCP and SNMP only work, if all necessary servers and clients are registered in this list. Configuration - HTTP 4.3.3 4.3.3.1...
  • Page 10: Configuration - Sensors

    Expert PDU energy 8310 Configuration Configuration - Sensors 4.3.4 4.3.4.1 Generate Messages Here you can configure if and at which Min-/Max-values the device shall send alerts via SNMP-Traps, Syslog or Email. 4.3.4.2 Peak measurement period Here, you can enter the time over which the peak values of the sensors shall be displayed: 30 minutes up to 24 hours. 4.3.4.3 Hysteresis Here you can specify a threshold that is reached after crossing a threshold in order to signal that falls below the threshold.
  • Page 11: Configuration - Snmp

    MIB. 4.3.5.1.3 SNMP-traps SNMP-Traps are system messages, sent via SNMP-protocol to different clients. On following events a SNMP-Trap will be dispatched: Min/Max-Alerts from the sensors You can find more information about configuration of SNMP at http://www.gude.info/wiki.
  • Page 12: Configuration - Syslog

    On following events a syslog message will be send: - Booting up - Activation/deactivation of syslog - sensor alarm You can find more information about configuration of Syslog in chapter Configuration - Syslog or have a look at http:// www.gude.info/wiki. 4.3.6.1 Enable Syslog Here you can activate Syslog.
  • Page 13: Configuration - E-Mail

    Syslog Port If syslog is active enter here the port number, that your Syslog server uses to receive syslog information. More information about Syslog you can find in chapter Syslog, on http://www.gude.info/wiki or ask our support team. Configuration - E-Mail 4.3.7...
  • Page 14: Chapter 5 Features

    In order to update the firmware the program GBL_Conf.exe and the latest firmware are needed. Start the device in bootloader mode and run the program GBL_Conf.exe. On the left side of the program window all Gude de- vices that are in the network are listed. Select the device, that should be updated, click on Program DeviceFirmware Update and determine the location of the new firmware.
  • Page 15: Factory Settings

    Please notice that all current settings will be deleted. The default settings will be loaded when the firmware of the device is re- started the next time. Support In case of further questions, about installation or operation of the device, please have look at www.gude.info/wiki or do not hesitate to contact our support (mail@gude.info). Contact Gude Analog- und Digitalsysteme GmbH Eintrachtstraße 113...
  • Page 16: Chapter 8 Declarations Of Conformity

    Technische Dokumentation zur Beurteilung von Elektro- und Elektronikgeräten hinsichtlich EN 50581:2012 der Beschränkung gefährlicher Stoffe / Technical documentation for the assessment of elec- trical and electronic products with respect to the restriction of hazardous substances Köln, 09.07.2013 Dr. Michael Gude, Geschäftsführer / General manager, CEO...
  • Page 17 Expert PDU energy 8310 © 2014 Gude Analog- und Digitalsysteme GmbH 25.02.2014...