Advertisement

Quick Links

Manual
Expert Power Control 1202
Expert Power Control 1292
© 2018 Gude Analog- und
Digitalsysteme GmbH
Manual Ver. 2.4.3
from Firmware Ver. 1.6

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Expert Power Control 1292 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gude Expert Power Control 1292

  • Page 1 Manual Expert Power Control 1202 Expert Power Control 1292 © 2018 Gude Analog- und Digitalsysteme GmbH Manual Ver. 2.4.3 from Firmware Ver. 1.6...
  • Page 2 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 3: Table Of Contents

    Power Port Menu ..................31 2.4.2.1.2 Status Menu ....................32 2.4.2.1.3 Parameter Description ................32 2.4.3 Power Port Commands ..................33 2.4.4 Security ........................35 Configuration Power Ports ......................37 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 4 Console Cmd 1202 ....................69 4.7.2 Console Cmd 1292 ....................75 Modbus TCP ......................82 Messages ......................86 Support Data Security ......................89 Contact ......................... 89 Declaration of Conformity ..................90 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 5 Table of contents FAQ ........................90 Index Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 6 Device Description...
  • Page 7: Device Description Security Advice

    The Expert Power Control 1202 / 1292 can switch 4 different load outputs. The device has the following features: · 4 Power Ports individually switchable directly on the device, via HTTP(S), SNMP · Case allows mounting in 19 inch racks Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 8 · GSM admin and user access for all Power Ports definable · For pre-paid and post-paid SIM cards (SIM card not included) · Triband network · FreeCall: Predefined action upon toll-free incoming call from a specific number Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 9: Installation

    8. 4 plain text displays (on/off) for the state of the Power Ports 1. Sensor connector 2. Antenna terminal (only EPC 1292) 3. Ethernet connector (RJ45) 4. SIM card slot (only EPC 1292) Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 10: Overvoltage Protection

    The state of the protection is indicated on the front panel by a red flash. A not visible flash means, that the protection is active, a red flash symbolizes that the overvoltage Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 11: Technical Specifications

    -20°C - 70 °C · Storage temperature 0% - 95% (non-condensing) · Humidity Case Synthetic Measurements 484mm x 46mm x 74mm (L x H x W) Weight approx. 1050 g Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 12: Electrical Measurement

    One external sensor can be connected to the Expert Power Control 1202 / 1292. The following sensors are currently available Temperature-Sensor 7001 Cable length Connector Mini-DIN Measurement range -20°C to +80°C at ±2°C (maximum) and ±1°C (typical) Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 13 A click on the link in the "Name" column opens the display of the Min and Max values. The values in a column can be reset using the "Reset" button. The "Reset" button in the name column deletes all stored Min and Max values. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 14: Operating

    Operating...
  • Page 15: Operating The Device Directly

    Access the web interface: http://"IP-address" and log-in. The web page provides an overview of the switching state, energy measurement val- ues, as well as the external sensors, provided that they are connected. When a single Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 16 Optionally the device can be switched via a Perl script or external tools like wget. More information is available on our support wiki at www.gude.info/wiki. For devices with a GSM module (Expert Power Control 1292), additional reception in- formation, the prepaid credit and the own call number are displayed. An overview of the GSM activities can be expanded.
  • Page 17: Maintenance

    For devices with relays, entering or exiting the bootloader mode does not change the state of the relays as long as the operating voltage is maintained. The GBL_Conf.exe program is available free of charge on our website www.gude.info and can also be found on the enclosed CD-ROM.
  • Page 18: Maintenance Page

    2.3.1 Maintenance Page This section provides access to important functions such as Firmware Update or Re- start Device. It is advisable to set an HTTP password for this reason. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 19: Configuration Management

    Flush DNS Cache: All entries in the DNS cache are discarded and address resolutions are requested again. 2.3.2 Configuration Management The device configuration can be saved and restored in the maintenance area Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 20 It can happen that events are triggered at the same time as the device is configured. One should therefore: a) disable the function b) completely parametrize c) reactivate the function Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 21: Bootloader Activation

    Abandonment of the Bootloader Mode 1) via push button: · Hold both buttons for 3 seconds (only if the device has 2 buttons) Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 22: Gsm

    Here, the device menu is operated using DTMF codes. This type of operation can also be carried out automatically. Preparing for GSM operation If you are using a new SIM card, please take note: Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 23 GSM module is deactivated. Signal Tower indicator on GSM module activated. Signal Strength Indicator · 0 bars - no signal · 2 bars - approx. 30% · 4 bars - approx. 70% Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 24: Sms

    Reset Power Port 6, Portcode 0123 %port reset p0123 Switch on Power Port 1, without Portcode %port on 1 Answer (example): Device name: epc007 Power switch: Port 1 off -> on Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 25: Powerport: Advanced Switching (Batchmode)

    (according to the current power port configuration), as if the device performs a cold start. Format %coldstart {mastercode} Example: %coldstart m0123 Answer: Device name: epc007 Switch sequence: coldstart Account Credit: Credit: 130.50 Eur Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 26: Configuration: Read

    2.4.1.1.6 Configuration: Write Format %config set [config-name] [config-value] {Mastercode} [config-name] code telbook gsmstatus temp response error portname adminnum tempmin tempmax Example: %config set code off m1234 Answer: Config: code = off Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 27: Configuration: All Parameter

    VoiceCall Phone number adminnum max. 15 chars for SMS mes- sages Minimum value tempmin '-20' .. '0' for temperature alerts Maximum value tempmax '0' .. '90' for temperature alerts Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 28: Sensors: Query State

    Account credit: Credit: 130.50 Eur 2.4.1.2 SMS replies 2.4.1.2.1 SMS command replies A command reply SMS looks like: Device name: [name] prefix [response text] Command specific reply Account credit: [x] Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 29: Status Change Report Sms

    [powerport] = 'Port 1' .. 'Port 99' (or Config:portname) [s] = batchmode, toggled, Coldstart Temperature state: [val] [val] = 'over the MAX limit', 'under the MIN limit' Account credit: [x] Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 30: Voice Call

    - enter Status Menu 1111 - Mastercode For the navigation in menus the following commands are required: *99# - Jump to Main Menu *98# - Return to prev Menu *97# - Help Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 31: Power Port Menu

    Here you can choose and switch Power Ports or request the status of a Power Port. Example: - Switch to Power Port menu - Choose Power Port 5 *01# - Switch on Or connected into one command: *1501# Example: Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 32: Status Menu

    [sq] - Status Query - Values '01' .. '89' Special Menu Commands (90 .. 00) - 99 : Jump to Main Menu - 98 : return to prev Menu Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 33: Power Port Commands

    Powerport off, wait t7, Power Port on wait t7, on Batchmode: off, Powerport off, wait t8, Power Port on wait t8, on Batchmode: off, Powerport off, wait t9, Power Port on wait t9, on Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 34 Batchmode: Power Port toggle, wait t8, Power Port toggle, toggle wait t8, toggle Batchmode: Power Port toggle, wait t91, Power Port toggle, toggle wait t9, toggle Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 35: Security

    For this reason we recommend the code query. Access Phonebook Port/Maste Security Check rCode Anybody Very low Phonebook Check Normal Code Check High Phonebook and Very high Code Check Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 36: Configuration

    Configuration...
  • Page 37: Power Ports

    Initialization status(coldstart): This is the port state (on, off, remember last state) the port should be set when the device is turned on. The setting "remember last state" saves the last manually set state of the power port in the EEPROM. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 38: Watchdog

    You can monitor devices on your own network, as well as devices on an external net- work, e.g. the operating status of a router. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 39: Ethernet

    (e.g. it is doing a file system check), the server would probably exceed the trip- ping time of the watchdog. The server would be switched off and on again, and the file system check is restarted. This would be repeated endlessly. Ethernet Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 40: Ip Address

    Use manual IPv6 address settings: Activates the entry of manual IPv6 addresses. IPv6 status: Displays the IPv6 addresses over which the device can be accessed, and additionally DNS and router addresses. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 41: Ip Acl

    IPv6 device addresses, and to set two DNS addresses, and a gateway. 3.2.2 IP ACL Reply ICMP ping requests: If you enable this feature, the device responds to ICMP pings from the network. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 42: Http

    Users can log in by entering the user password in order to query the status in- formation and initiate switching operations. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 43: Protocols

    Active negotiation: The IAC negotiation is initiated by the server. Require user login: Username and password are required. Delay after 3 failed logins: After 3 wrong entries of username or password, the next lo- gin attempt is delayed. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 44: Syslog

    Syslog Server: If you have enabled Syslog Messages, enter the IP address of the server to which the syslog information should be transmitted. 3.3.3 SNMP SNMP-get: Enables the acceptance of SNMP-GET commands. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 45 MIB table: The download link to the text file with the MIB table for the device. More information about SNMP settings are available from our support or can be found on the Internet at www.gude.info/wiki. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 46: Radius

    Shared secret: Radius Shared Secret. Timeout: How long (in seconds) will be waited for a response from an Authentication Request. Retries: How often an authentication request is repeated after a timeout. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 47: Modbus Tcp

    Password is accepted by the configured Radius Servers. 3.3.5 Modbus TCP Enable Modbus TCP: Enables Modbus TCP support. Modus TCP port: The TCP/IP port number for Modbus TCP. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 48: Sensors

    1292). On this example screenshot the recipients "Paul" and "Mary" are enabled, SMS sending for "Peter" is disabled. Min/Max measurement period: Selects the time range for the sensor min/max values on the overview web page. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 49: Port Switching

    Example with "Maximum value" of 65 °C, "Minimum value" of 25 °C and hysteresis of 3 °C. The dotted line shows the hysteresis. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 50: E-Mail

    "On" or "Off" action is defined for a port, the port can never reach this state by ex- ceeding sensor values. Unless it is the initial state. E-Mail Enable E-Mail: Activates the e-mail dispatch of messages. Sender address: The e-mail address of the sender. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 51: Front Panel

    Button Lock: Disables the front buttons (activates the key lock) with the exception of the bootloader activation. Dark Display: The 7-segment display remains dark. Front button activity temporarily switches the display on. Default Display: Selects what sensor is displayed in the display. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 52: Gsm General

    Admin E-mail: Email address to which the GSM messages are sent. Enable DTMF/SMS access codes: When activated, the Mastercode or Portcode is needed to switch a port. Master code: Sets the GSM Mastercode. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 53: Gsm Misc

    GSM network after power-up. Enablevoice in voice call: If enabled, you hear voice samples when a call is coming in (Voicecall). machine-to-machine DTMF tones: Enables DTMF tones in voice steering. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 54: Gsm Phonebook

    This menu only appears when you insert a SIM card from a phone company that oper- ates outside of Germany. To receive necessary information, contact your wireless ser- vice provider. IMSI: Your IMSI number. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 55 The correct spelling is important to help the device recognizing whether the cur- rent balance is communicated in a message. Balance parsing string: Enter the query that you send to your provider to access your prepaid balance: E.g. *101# Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 56: Specifications

    Specifications...
  • Page 57: Ip Acl

    Leading zeros may be omitted within a block. The previous example can be rewritten 1234:4ef0:0:0:19:32ff:fe00:124 One may omit one or more successive blocks, if they consist of zeros. This may be done only once within an IPv6 address! 1234:4ef0::19:32ff:fe00:124 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 58: Radius

    / write status of Power Ports (relays) read / write names of Power Ports (relays) read / write status of Port start configuration read / write status Buzzer Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 59: Snmp

    To enforce limited access we recommend the use of DMZ or IP-ACL. SNMP v3 Because the device has no multiuser management, only one user (default name Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 60 96" can muster enough entropy for key lengths of "AES-192" or "AES-256". · From the foregoing considerations, we would recommended at present "HMAC- SHA-96" with "AES-128" as authentication and encryption method. Change in Trap Design Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 61: Device Mib 1202

    Below is a table of all device-specific OID 's which can be accessed via SNMP. In the numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise OID) was omitted at each entry in the table to preserve space. The example for a com- plete OID would be "1.3.6.1.4.1.28507.43.1.1.1.1".
  • Page 62 Resettable Forward Reactive Energy counter. epc1202RevEnergyActive .43.1.5.1.2.1.20.x Gauge32 Reverse Active Energy counter. epc1202RevEnergyReactive .43.1.5.1.2.1.21.x Gauge32 Reverse Reactive Energy counter. epc1202RevEnergyActiveReset- .43.1.5.1.2.1.22.x Gauge32 table Resettable Reverse Active Energy counter. epc1202RevEnergyReactiveReset- .43.1.5.1.2.1.23.x Gauge32 table Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 63: Device Mib 1292

    Below is a table of all device-specific OID 's which can be accessed via SNMP. In the numerical representation of the OID the prefix " 1.3.6.1.4.1.28507 " (Gude Enterprise OID) was omitted at each entry in the table to preserve space. The example for a com- plete OID would be "1.3.6.1.4.1.28507.50.1.1.1.1".
  • Page 64: Ssl

    DewPoint) TLS Standard The device is compatible with the standards TLSv1.0 to TLSv1.2. Due to lack of secur- ity, SSLv3.0 as well as RC4 and DES encryptions are deactivated. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 65 Usually OpenSSL is used to create an SSL certificate. For Windows for example, there is the Shining Light Productions light version of . There you open a command prompt, change to the directory "C:\OpenSSL-Win32\bin" and set these environment variables: set openssl_conf=C:\OpenSSL-Win32\bin\openssl.cfg Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 66 SSL session cache, so all other requests are just as fast as with other certificate lengths. For a quick response even on the first access, we recom- mend RSA 2048-bit certificates that offer adequate security, too. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 67: Console

    0 Numerical parameters can be entered with different bases. Here is an example of the decimal value 11: Base Input decimal (10) hexadecimal (16) octal (8) binary (2) 0b1011 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 68 (partially invisible). Editing The following edit functions are available when the terminal supports VT100, and Raw Mode is deactivated. Entered characters are inserted at the cursor position. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 69: Console Cmd 1202

    SMTP username email user show shows SMTP username email passwd set "{passwd}" sets SMTP password email passwd hash set "{passwd}" sets crypted SMTP password email testmail send test email Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 70 "{ip_address}" sets IPv4 address ip4 address show shows IPv4 address ip4 netmask set "{ip_address}" sets IPv4 netmask ip4 netmask show shows IPv4 netmask Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 71 {line_num} events set {OFF=0|ON=1} LEGACY - enables events on/off linesensor {line_num} events show LEGACY - shows if events are enabled linesensor {line_num} events type set LEGACY - enables different event types Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 72 {port_num} watchdog bootretries set {num} sets port watchdog retry boot timeout port {port_num} watchdog bootretries show hows port watchdog retry boot timeout radius enters cmd group "radius" radius {PRIMARY=0|SECONDARY=1} enabled enables radius client Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 73 {OFF=0|ON=1} blocks panel buttons when not enabled system panel enabled show shows if panel buttons are enabled Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 74 Absolute Active Energy Resettable Absolute Reactive Energy Resettable VARh Residual Current Dependent on the device model Residual Current may not be supported External Sensor Type Table "{sen_type}" Constants "{7x01=0|7x04=0|7x02=1|7x05=1|7x06=2}" Index Description Products Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 75: Console Cmd 1292

    SMTP connection security SSL=2} email security show shows SMTP connection security email auth set {NONE=0|PLAIN=1|LOGIN=2} sets email authentication email auth show show email authentication email user set "{username}" sets SMTP username Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 76 "{email_addr}" sets status email recipient address gsm admin email show shows status email recipient address Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 77 "{ip_address}" sets IPv4 address ip4 address show shows IPv4 address ip4 netmask set "{ip_address}" sets IPv4 netmask ip4 netmask show shows IPv4 netmask Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 78 {line_num} {energy_sensor} {BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2| sets Port state for Power Port Switching actions BELOWMAX=3} state set {OFF=0|ON=1| DISABLED=2} linesensor {line_num} {energy_sensor} shows Port state for Power Port Switching actions {BELOWMIN=0|ABOVEMIN=1|ABOVEMAX=2| Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 79 {port_num} watchdog pingretries set {num} sets port watchdog ping retries port {port_num} watchdog pingretries show shows port watchdog ping retries port {port_num} watchdog retrybooting set sets port watchdog retry booting to on/off {OFF=0|ON=1} Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 80 "{dns_name}" sets address of syslog server syslog server show shows address of syslog server system enters cmd group "system" system restart restarts device Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 81 Absolute Active Energy Absolute Reactive Energy VARh Absolute Active Energy Resettable Absolute Reactive Energy Resettable VARh Residual Current Dependent on the device model Residual Current may not be supported Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 82: Modbus Tcp

    · Number of energy sensors · Measured values of energy sensors · Measured values of the external sensors This chapter is general for all Gude devices. Depending on the device type, some ports or certain sensors are not available. Address Range:...
  • Page 83 1 to 0x400 Byte count 1 Byte Outputs Value n x 1 Byte each Bit represents a state Response Code 1 Byte 0x0f Starting Address 2 Bytes 0x00 to 0x3ff Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 84 Energy Sensors: We distinguish the line sensors (which correspond to the input circuits) and the port sensors, which measure the energy that is passed over the switched port. The meas- Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 85 For measured values such as "Neut- ral Current", which are independent of the phase, the same value is returned for all phases. Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 86: Messages

    SNMP Traps are system messages that are sent via the SNMP protocol to different re- cipients. SNMP traps are triggered by the following events: · Switching of the Power Ports Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 87 · Exceeding of the max / min values of attached sensors · State change of digital sensor input ports · Exceeding of max / min values of the measured power consumption · Condition change of overvoltage protection Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 88: Support

    Support...
  • Page 89: Data Security

    Support Support You will find the latest product software on our website at www.gude.info available for download. If you have further questions about installation or operation of the unit, please contact our support team. Furthermore, we present in our support wiki at www.gude.info/wiki FAQs and configuration examples.
  • Page 90: Declaration Of Conformity

    This product from the Expert Power Control 1202 / 1292 series is in conformity with the European directives for CE marking applicable to this product. The complete CE declaration of conformity for this product can be found on the website www.gude.info in the download section of the product.
  • Page 91 GBL_Conf.exe Select button Sensors 12, 48 GSM General signal strength GSM Misc SIM card slot GSM Phone SMS Commands GSM Provider SMS replies GSM SIM Card SNMP 44, 59 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 92 Index Start-up the device Status LED Status-LED syslog - T - Technical Specifications - V - Voice Call - W - Watchdog Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...
  • Page 93 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH 10/16/2018 Expert Power Control 1202/1292 © 2018 Gude Analog- und Digitalsysteme GmbH...

This manual is also suitable for:

Expert power control 1202

Table of Contents